Photo Eye, Safety Edge, Safety Loop:
Normally Closed (NC) of safety device
= FSW CL ter minal of CN4 block on gate opener
control board.
Common (COM) or Ground (GND) of safety device
= COM ter minal of CN4 block on gate
opener control board.
24V Power positive (+) or (24V) or (PWR) of safety device
= 24V+ ter minal of CN1 block
on gate opener control board.
24V Power negative (-) or (GND) or (PWR) of safety device
= 24V- terminal of CN1 block
on gate opener control board.
*Remove safety jumper from FSW CL terminal if using a safety device.
Solenoid Gate Lock:
Positive Lead of lock
= ELS terminal of CN2 block on gate opener control board.
Negative Lead of lock
= ELS terminal of CN2 block on gate opener control board.
Magnetic Gate Lock:
Magnetic gate locks must have their own power supply and their own
relay.
Coil of relay for magnetic lock
= ELS terminal of CN2 block on gate opener control board.
Coil of relay for magnetic lock
= ELS terminal of CN2 block on gate opener control board.
Connect positive lead of the power supply directly to the positive lead of the mag lock.
Connect negative lead of the power supply to the N/C terminal of the relay.
Connect the COM terminal of the relay to the negative lead of the mag lock.
Accessories Wiring