Essick Excel N46W Скачать руководство пользователя страница 8

Instructions to Convert Unit to Vertical Duct Configuration 

 

1. Remove the 13 screws holding the Duct in place.

 

2. Replace the 4 screws removed from the Top Pan.

 

3. Turn the Duct 90 degrees counter-clockwise.  Be careful not to unplug the switch from the wiring harness.

 

4. Align the Duct with the 3 holes at the top of the Front Panel (just below the Top Pan).

 

5. Insert 3 screws at the top and bottom of the duct.

 

 

6. Place the Duct Mount Strips (found in bottom of cooler) over the side Duct Flanges and insert screws 3 each side into 

the holes provided (3 screws will be in installation kit).

 

 

 

Proceed with the installation as normal.  The Side Sealer Channels will go on the same flanges as for a horizontal duct.  
You may use the Side Sealers provided to close off the window above your cooler’s duct.   
 

 

LIMITED WARRANTY 

 

This warranty is extended to the original purchaser only.

  It does not cover damages incurred during shipping or 

through accident, neglect, or abuse by the owner.  Champion Cooler/Essick Air Products does not authorize any person 
or representative to assume any other or different liability in connection with this cooler. 
 

TERMS AND CONDITIONS OF WARRANTY

 

The 

BOTTOM PAN 

is guaranteed against leakage 

due to rusting out

 for 

Eight Years

.  All other original parts provided 

by Champion Cooler/Essick Air Products are warranted against defects in material or factory workmanship for One Year. 
 

EXCLUSIONS FROM THE WARRANTY

 

Champion Cooler/Essick Air Products is not responsible for incidental or consequential damage resulting from any 
malfunction. 
 
Champion Cooler/Essick Air Products is not responsible for any damage occurring from the use of water softeners, 
chemicals, descale material, or if a higher horsepower motor than what Champion Cooler/Essick Air Products 
recommends is used in the unit. 
 
Champion Cooler/Essick Air Products is not responsible for the cost of service calls to diagnose cause of trouble, or labor 
charge to repair and/or replace parts. 
 

HOW TO OBTAIN SERVICE UNDER THIS WARRANTY

 

Contact the Dealer where you purchased the evaporative cooler.  If for any reason you are not satisfied with the response 
from the Dealer, contact Customer Service Department: Essick Air Products Inc. 5800 Murray Street, Little Rock, 
Arkansas 72209.  1-800-643-8341.

 

 

Содержание Excel N46W

Страница 1: ...assed through wetted filters and is converted to refreshingly cooled air Champion Essick coolers make the best use of the evaporative process by controlling the flow of water spreading the water evenl...

Страница 2: ...rackets as shown 2 Cut the Side Sealer Channels so that two of them will span the window when butted together Place two of the channels on the bottom duct flange as shown 3 Place the Cooler in the cen...

Страница 3: ...o leak It is best to secure the connections turn on the water and then snug the fitting until leaking stops ADJUSTING WATER LEVEL AND FLOAT VALVE To adjust water level bend the float valve rod Check a...

Страница 4: ...even pad wetting Pump clogged or failed Pads plugged with dirt and water deposits Check incoming water line float and water distributor for blockages and clear Adjust window openings Level water trays...

Страница 5: ...pad 4 Clean water deposits from the louver If the paint is chipped or rust spots occur sand the spots and paint louver with a rust resistant exterior paint 5 Place new filter in louver and tuck in to...

Страница 6: ...Filter Set 27 516153 516157 503314 503314 Filter Side 27 516155 503314 503314 503314 Filter Back 28 504258 504262 504263 504263 Louver Side 28 514260 504263 504263 504263 Louver Back 29 504266 504267...

Страница 7: ...7 23 Models Modelos RWC35 RN35W RWC46 RN46W RWC50 RN50W Models Modelos WC35 N35W WC46 N46W WC50 N50W...

Страница 8: ...on or representative to assume any other or different liability in connection with this cooler TERMS AND CONDITIONS OF WARRANTY The BOTTOM PAN is guaranteed against leakage due to rusting out for Eigh...

Отзывы: