Essick Excel N46W Скачать руководство пользователя страница 2

SAFETY GUIDE LINES & CAUTIONS 

When Installing 

When Operating 

When Servicing 

Make sure that unit is installed on a sound 
structure that will support the full operating 
weight of the cooler.  See page 4. 

Make sure that circuit cooler is plugged into is 
equipped with a (slow blow) breaker large 
enough to support the full amperage of the 
cooler. 

Always Unplug the cooler before attempting 
service of any kind. 

Before attempting to hang the cooler in the 
window, remove the louvers to reduce weight. 

To reduce the risk of fire or electrical shock, DO 
NOT use this fan with any Solid-state speed 
control device. 

Be sure to disconnect unit from power 
source before servicing.  If not, it can be 
turned on from inside the house and start 
unexpectedly. 

Do NOT connect power to cooler before 
installation is complete. 

This cooler is equipped with an 

UUUU

automatic

UUUU

 

thermally protected motor.  If it shuts off on its 
own for any reason, 

UUUU

it can restart without 

warning

UUUU

If the motor shuts off because of thermal 
overload, check into the problem 
immediately.  If allowed to continue, 
permanent damage will occur. 

 

MOUNTING 

 

To install this cooler, the following tools are required: 

 Adjustable wrenches 

 Screwdrivers 

 Electric drill 

  3/16” drill bit 

 Level 

 
1. Loosen the Adjustment Screw in the Stand-Off Bracket.  Remove the Spacer-Rod 

from the installation package and insert them into the Stand-Off brackets as shown. 

 
2. Cut the Side Sealer Channels so that two of them will span the window when 

butted together.  Place two of the channels on the bottom duct flange as shown. 

 
3. Place the Cooler in the center of the window with the bottom duct flange resting 

against the sill. 

 
4. Pull out the Spacer-Rods so as to allow the Rubber Feet to rest against the side of 

the house.  Tighten the Adjustment Screws. 

 
5. Lower the window to rest on top of the duct behind the top duct flange. 
 
6. Fasten a stop above the inside window sash to prevent the window from being 

raised.  Raising the window may cause the cooler to fall. 

 
7. Adjust the Spacer-Rods to level the cooler.  This will ensure proper water flow to the 

pads. 

 
8. Install the Chain Supports. 

a. Drill pilot holes in the window frame, 3 feet above the top of the duct and the width 
of the cooler apart.  Install the Screw-Hooks in these pilot holes to the full depth of the 
thread. 
b. Hook one end of each Chain over each Screw-Hook. 
c. Place S-Hooks in the in the holes at the top-rear of the cooler. 
d. Place the opposite end of the S-Hooks in the free end of each Chain.  Make sure 
the chains are taut, but not so tight they pull the bottom of the cooler away from the 
wall. 

9. Install the Side Sealer Panels.  These panels are the correct height, but need to be 

trimmed to fit the width of your window.  Trim the panels so that they reach from the 
window frame to the side of the duct.  Slide the panels in the channels you placed on 
the bottom duct flange.  Install the remaining Side-Sealer Channels over the top duct 
flange and the Side-Sealer Panels.

 

 

 

Содержание Excel N46W

Страница 1: ...assed through wetted filters and is converted to refreshingly cooled air Champion Essick coolers make the best use of the evaporative process by controlling the flow of water spreading the water evenl...

Страница 2: ...rackets as shown 2 Cut the Side Sealer Channels so that two of them will span the window when butted together Place two of the channels on the bottom duct flange as shown 3 Place the Cooler in the cen...

Страница 3: ...o leak It is best to secure the connections turn on the water and then snug the fitting until leaking stops ADJUSTING WATER LEVEL AND FLOAT VALVE To adjust water level bend the float valve rod Check a...

Страница 4: ...even pad wetting Pump clogged or failed Pads plugged with dirt and water deposits Check incoming water line float and water distributor for blockages and clear Adjust window openings Level water trays...

Страница 5: ...pad 4 Clean water deposits from the louver If the paint is chipped or rust spots occur sand the spots and paint louver with a rust resistant exterior paint 5 Place new filter in louver and tuck in to...

Страница 6: ...Filter Set 27 516153 516157 503314 503314 Filter Side 27 516155 503314 503314 503314 Filter Back 28 504258 504262 504263 504263 Louver Side 28 514260 504263 504263 504263 Louver Back 29 504266 504267...

Страница 7: ...7 23 Models Modelos RWC35 RN35W RWC46 RN46W RWC50 RN50W Models Modelos WC35 N35W WC46 N46W WC50 N50W...

Страница 8: ...on or representative to assume any other or different liability in connection with this cooler TERMS AND CONDITIONS OF WARRANTY The BOTTOM PAN is guaranteed against leakage due to rusting out for Eigh...

Отзывы: