Essick Excel N46W Скачать руководство пользователя страница 3

INSTALL OVERFLOW AND DRAIN 

1. Slide the Rubber Washer over the Drain Bushing and push through the hole in the 

bottom of the cooler from the top side. 

2. Secure the Drain Bushing from beneath the pan with the Lock Nut.  Make sure the 

Rubber Washer does not twist while tightening, which could cause it to leak.  

UUUU

DO NOT 

OVERTIGHTEN.

UUUU

 

3. Thread the Overflow Tube into the Drain Bushing and 

HAND TIGHTEN

.

 

 

4. If leakage occurs after Reservoir is full, retighten the Overflow Pipe until leaking stops.  

A small amount of silicone caulk may be used if necessary.

 

 

 

FLOAT VALVE INSTALLATION 

 

1. Place the threaded portion of the Float Valve through the hole provided in the Corner 

Post from the inside. 

 
2. Slip the Fiber Washer over the threaded portion outside the corner post and secure with 

the Nut.  Be sure the Float does not turn while you are tightening the Nut.

 

 

 

WATER LINE CONNECTION 

 

Find the closest outside water faucet, and install a Water Connection Kit (not included with 
cooler) as shown.  If an exterior faucet is not available, locate the closest cold water pipe 
and install a saddle valve assembly. 

 

Route tubing to cooler.  Place Compression Nut and Ferrule over end of tubing.  Insert the 
tubing into float valve and tighten Compression Nut to secure.  

NOTE:

 Over tightening the 

compression fitting will cause that fitting to leak.  It is best to secure the connections, turn 
on the water, and then snug the fitting until leaking stops. 
 

ADJUSTING WATER LEVEL AND FLOAT VALVE 

 

  To adjust water level, bend the float valve rod. 

  Check all water connections for leaks. 

  Make sure the Float Valve cuts off completely when the desired water level has been 

reached (½” to ¾” below top of Overflow Tube).  If the float does not stop the water 
completely, the water level will rise and run out the Overflow Tube. 

  Double check the Overflow Tube for leaks. 

 

START UP 

 

1. Plug in the electrical cord to a standard grounded receptacle.  Be sure the Circuit Breaker protecting the receptacle is of 

sufficient size. 

2. Open windows in rooms where you want cooling to be directed. 
3. Turn the cooler to the High Fan position.  Observe the amount of air being delivered.  Note: on cool nights (or days) or 

when the humidity level is high, the fan positions may be used for ventilation purposes. 

4. Turn the cooler to the Low Fan position.  This should significantly reduce the amount of air being delivered. 
5. Turn the cooler to the Pump Only position. The pump should run and not the fan. Check to see that water is flowing 

from all three Water Trays. 

6. Turn the cooler to the High Cool position.  Check to see that all three Pads are wetting evenly with no dry patches.  The 

Pads may take up to 20 minutes to wet fully.  If the Pads have dry patches, you can adjust the level of each Water Tray 
by screws on each end. 

7. Adjust window openings to achieve desired cooling level. 

Reservoir

Ferrule

Faucet

Содержание Excel N46W

Страница 1: ...assed through wetted filters and is converted to refreshingly cooled air Champion Essick coolers make the best use of the evaporative process by controlling the flow of water spreading the water evenl...

Страница 2: ...rackets as shown 2 Cut the Side Sealer Channels so that two of them will span the window when butted together Place two of the channels on the bottom duct flange as shown 3 Place the Cooler in the cen...

Страница 3: ...o leak It is best to secure the connections turn on the water and then snug the fitting until leaking stops ADJUSTING WATER LEVEL AND FLOAT VALVE To adjust water level bend the float valve rod Check a...

Страница 4: ...even pad wetting Pump clogged or failed Pads plugged with dirt and water deposits Check incoming water line float and water distributor for blockages and clear Adjust window openings Level water trays...

Страница 5: ...pad 4 Clean water deposits from the louver If the paint is chipped or rust spots occur sand the spots and paint louver with a rust resistant exterior paint 5 Place new filter in louver and tuck in to...

Страница 6: ...Filter Set 27 516153 516157 503314 503314 Filter Side 27 516155 503314 503314 503314 Filter Back 28 504258 504262 504263 504263 Louver Side 28 514260 504263 504263 504263 Louver Back 29 504266 504267...

Страница 7: ...7 23 Models Modelos RWC35 RN35W RWC46 RN46W RWC50 RN50W Models Modelos WC35 N35W WC46 N46W WC50 N50W...

Страница 8: ...on or representative to assume any other or different liability in connection with this cooler TERMS AND CONDITIONS OF WARRANTY The BOTTOM PAN is guaranteed against leakage due to rusting out for Eigh...