Essick Excel N46W Скачать руководство пользователя страница 4

WIRING DIAGRAM 

 

CAUTION: Always unplug cooler before opening or attempting service of any kind. 

WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. 

 

COOLER SPECIFICATIONS 

Model Height Width  Depth  Amps 

Shipping Weight 

Operating Weight 

(R)WC50/(R)N50W 35” 

34” 

34” 

8.4 

165 

249 

(R)WC46/(R)N46W 35” 

34” 

34” 

7.4 

165 

249 

(R)WC44 35” 

34” 

28” 

7.4 

147 

217 

(R)WC35/(R)N35W 31” 

32” 

21” 

7.4 

135 

184 

 

TROUBLE SHOOTING 

Problem Cause  Remedy 

Motor cycles on and off 

  Excessive belt tension 

  Blower shaft not spinning freely 

  Extension cord (if one used) too long 

  Circuit breaker not large enough 

  Adjust belt tension 

  Lubricate or replace bearings 

  Choose a shorter or heavier gauge cord 

  Consult a licensed electrician 

Fails to start 

  No electrical power 

  Circuit breaker tripped or fuse blown 

  Check all electrical connections and cords 

  Reset circuit breaker or replace fuse 

Water draining from overflow 

 Float 

improperly 

adjusted 

 Adjust 

float 

Blower vibrates excessively 

  Belt or pulley loose 

  Blower wheel out of balance or out of 

alignment 

  Debris in blower housing 

  Adjust belt or tighten pulley 

  Replace the blower wheel 

 

 Clear 

debris 

Not cooling 

  Blocked water lines 

 

  Windows opened too little or too much. 

 Uneven 

pad 

wetting 

 

  Pump clogged or failed 

  Pads plugged with dirt and water deposits 

  Check incoming water line, float and water 

distributor for blockages and clear. 

  Adjust window openings 

  Level water trays, check for blocked water 

slots in water trays 

  Clean or replace pump 

 Replace 

pads 

 

This cooler is equipped with an 

UUUU

automatic

UUUU

 thermally protected motor.  If it shuts off on its own for any reason, 

UUUU

it 

can restart without warning

UUUU

 

Your cooler may be controlled by a rotary switch (MANUAL CONTROLS) or by a touch pad/remote control. See below for 
functions. 

Note: pressing the ON/OFF button while the unit is running will turn off power to the entire unit.  Pressing the button again 
will turn the unit back on at the same setting, which the unit was at when it was turned off.

Switch Operation 

Remote Control Operation 

OFF 

Fan off 

Pump off 

PUMP ONLY 

Fan off 

Pump on 

ON/OFF 

Controls power to unit.  Does not change fan speed or turn 
Pump on or off. 

HIGH COOL 

Fan high speed 

Pump on 

LOW COOL 

Fan low speed 

Pump on 

FAN 

Controls Fan speed.  Press once for high speed (HI light on).  
Press again for low speed (LO light on).  Press again to turn 
fan off (HI and LO lights off). 

HIGH VENT 

Fan high speed 

Pump off 

LOW VENT 

Fan low speed 

Pump off 

PUMP 

Controls Pump.  Press once for pump on (PUMP light on).  
Press again for pump off (PUMP light off). 

Black - Hi

Red - Low

White - Common

Green - Ground

Motor

Pump

Switch

Wiring Harness

Motor Cord

Manual Control

Содержание Excel N46W

Страница 1: ...assed through wetted filters and is converted to refreshingly cooled air Champion Essick coolers make the best use of the evaporative process by controlling the flow of water spreading the water evenl...

Страница 2: ...rackets as shown 2 Cut the Side Sealer Channels so that two of them will span the window when butted together Place two of the channels on the bottom duct flange as shown 3 Place the Cooler in the cen...

Страница 3: ...o leak It is best to secure the connections turn on the water and then snug the fitting until leaking stops ADJUSTING WATER LEVEL AND FLOAT VALVE To adjust water level bend the float valve rod Check a...

Страница 4: ...even pad wetting Pump clogged or failed Pads plugged with dirt and water deposits Check incoming water line float and water distributor for blockages and clear Adjust window openings Level water trays...

Страница 5: ...pad 4 Clean water deposits from the louver If the paint is chipped or rust spots occur sand the spots and paint louver with a rust resistant exterior paint 5 Place new filter in louver and tuck in to...

Страница 6: ...Filter Set 27 516153 516157 503314 503314 Filter Side 27 516155 503314 503314 503314 Filter Back 28 504258 504262 504263 504263 Louver Side 28 514260 504263 504263 504263 Louver Back 29 504266 504267...

Страница 7: ...7 23 Models Modelos RWC35 RN35W RWC46 RN46W RWC50 RN50W Models Modelos WC35 N35W WC46 N46W WC50 N50W...

Страница 8: ...on or representative to assume any other or different liability in connection with this cooler TERMS AND CONDITIONS OF WARRANTY The BOTTOM PAN is guaranteed against leakage due to rusting out for Eigh...

Отзывы: