ERM Configuration
Input Requirements
The ERM accepts 12 - 24V AC/DC. An optional battery charging
module and rechargeable gel cells are available to keep the
system operational for up to 50 hours during a power interruption.
System and Keypad current draw (max) is as follows:
!
Standby: 120mA
!
During Operation: 230mA
Output Capabilities
Main Relay
The Main Relay will activate either a Fail-Safe or a Fail-Secure
(Non Fail-Safe) electronic locking device or other equipment. It
may also be configured as a dry contact relay output to control a
gate operator or garage door opener (Set Door Open Time to 1
second). The main output is programmable from 01 to 99 seconds
with optional timed or manual latching.
Output A
A Relay Contact output that can be programmed for one of the
following:
1. CCTV or Light Controller - First key press or ProxCard® II
(“card”) presentation to the K-Prox label area triggers a Timed
Output (1 to 99 seconds).
2. Auxiliary Output - Manual Control or Timed Output (1 to 99
seconds).
3. Second Door - Users can be assigned to open a 2nd door.
4. Doorbell - Press # at the Keypad to trigger a 1 second output
for a doorbell (not included).
Содержание Encoded Keyless Entry
Страница 4: ...Essex Electronics Inc 805 684 7601 800 KEY LESS fax 805 684 0232 keyless com iii...
Страница 34: ...Essex Electronics Inc 805 684 7601 800 KEY LESS fax 805 684 0232 keyless com 30 Notes...
Страница 35: ...31 Essex Electronics Inc 805 684 7601 800 KEY LESS fax 805 684 0232 keyless com Notes...
Страница 40: ...Essex Electronics Inc 805 684 7601 800 KEY LESS fax 805 684 0232 keyless com...