7
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
!
!
!
!
!
K-Prox Configuration
Voltage Selection
The factory default setting for the Keypad and Prox Reader
voltage is 12-24VDC. Verify that the jumpers are removed or
placed over only one pin. Do not set either for 5V.
Keypad Output Selection
Once the voltage jumper is verified or correctly set:
1. Remove power.
2. Jumper the two pins above the connector labeled "CONFIG.”
3. Apply appropriate power. (You should hear 4 beeps and the
RED LED will flash and the GREEN LED will be solid).
4. Now that the Keypad is in configuration mode, enter 98
followed by #. You should hear 3 beeps indicating successful
configuration. If you hear a long error beep, re-enter 98
followed by #. To change the audible beep, proceed as
follows. Otherwise, go to Step 5.
To change the audible beep, enter
Code
Audible Beep
201 #
Normal Beep (factory default)
200 #
Short Click (quieter)