29
4.2.7
Write Page (0x07)
Table 4.7
The Write Page command takes as arguments the first page address to be written (Page Address), the number of
pages to be written (Write Length) and the byte offset in the data buffer (Data Buffer Offset). If any of the pages to
be written are password protected, then a Password Authentication is necessary before doing a write operation. If
write fails, the Result Register is updated with
an ‘
error
’
value and the command execution terminates. After
successful communication, the data is transferred from the data buffer to the first page. This Command continues to
write to subsequent pages if the Write Length is higher than 1. If everything goes well all bytes are copied from the
Data Buffer starting from the Data Buffer Offset, and the Result Register is updated with
a ‘
No Error
’
value.
Command Number
Command Name
Valid Tag Types
Argument Offset [bytes]
0x00
0x01
0x02
Argument Name
Page Address
Write Length
Data Buffer Offset
Argument Size [bytes]
0x01
0x01
0x01
Argument Description
Address of the first
page in the memory to
which the data is to be
written.
Number of pages to
write. Value has to be
larger than 1.
Buffer offset in bytes
from where the data to
be written to the tag is
to be taken. Total write
size and the offset
cannot exceed the data
buffer length.
Mifare Ultralight, Mifare Ultralight EV1, NTAG