Page 41
PROGRAMMING VIA TELEPHONE
RELAY-BASED
NOTIFICATION
OF EXTERNAL
POWER FAILURE
AND/OR MOBILE
NETWORK
LOSS
(4)
**94*X#
X: option, from 0 to 6
0=
notifications disabled
1= the relay RL2 is deactivated in case of external
power failure
2= the relay RL2 is deactivated in case of mobile
network loss
3= the relay RL2 is deactivated in case of external
power failure or in case of mobile network loss
4= the relay RL2 is activated in case of external
power failure
5= the relay RL2 is activated in case of mobile
network loss
6= the relay RL2 is activated in case of external
power failure or in case of mobile network loss
RELAY RL1
ACTIVATION
**95*X#
X: option, from 0 to 1
0= to deactivate the relay
1= to activate the relay
RELAY RL1
PULSE
**96*XX#
XX:
seconds pulse duration, from 01 to 99
RELAY RL2
ACTIVATION
**92*X#
X: option, from 0 to 1
0= to deactivate the relay
1= to activate the relay
RELAY RL2
PULSE
**93*XX#
XX:
seconds pulse duration, from 01 to 99
INPUT
ACTIVATION
NOTIFICATION
SETTING
**42*X
…
X*X
…
X#
X…X: telephone number to which the SMS or CLI calls
for notification of activation of inputs are sent
**42#
Deleting
**43*X#
X: option, from 0 to 1
0=
notification sent via CLI call
1
=
notification sent via SMS (“Generic tech alarm“;
customizable text)
IN1 INPUT
SETTING
**71*X#
X: option, from 0 to 1
0= IN1 input normally open
1= IN1 input normally closed
**70*X#
X: option, from 1 to 3
1= minutes
2= seconds
3= counter
**72*XX#
XX: input activation duration (in minutes or seconds)
or number of input activations (if counter) required to
send the notification