6.
Once you have got all the delays for the different camera models, you need to work out the
differences between the cameras. For Example:
If you have 2 different camera models; 1 with a delay of 113ms and another with a delay of 61ms;
you need to subtract the fastest cameras (61ms) from the slowest cameras (113ms). The answer
that you get is the delay that you need to apply to the fastest cameras so that they fire at the same
time as the slow cameras.
Slowest camera (113ms) - fastest camera (61ms) = delay (52ms)
Assigning the delays.
7.
Now that you have got your delay for the fastest cameras in your array, you need to assign it to
the outputs that your fast cameras are connected to. If you have the fast cameras connected to
ports 4, 5 & 6 you would assign the delay to these ports so that they would fire at the correct time.
Figure 14
- TriggerBoxController software
You are now ready to fire and should have all your cameras in sync when firing. If your cameras are
still out of sync by a little bit, try increasing or decreasing the delay and see if this helps.
29
Содержание TriggerBox
Страница 1: ......