EsiWelma
®
s.r.l.
- 2 -
E117.602_En
2.
Installation and positioning
Conform to the permitted temperature and humidity conditions (See Technical Specifications).
Installation can be done:
By wall-mounting using 2 screws.
In a 3 module, type "503" built-in box.
Since carbon monoxide has a specific weight similar to that of air, it will be concentrated near the same height as the appliance
that manifests combustion defects or that is located in premises with insufficient ventilation.
Install about 2 metres (minimum 1 metre, maximum 3 metres) from the gas-operated appliance and at standard face height of
the occupants in those premises; example: 130 - 170 cm in the kitchen, 50 - 100 cm in the bedroom.
The detector must not be installed:
•
Outdoors
•
Too close to stoves, cooking appliances and, more in general, to gas appliances
•
Near sinks and taps
•
Near exhaust hoods, windows, fans etc.
•
In areas where dirt and/or dust can clog the front grille of the detector
•
Where the temperature or humidity exceeds the detector's operating limits
•
In closed spaces (behind curtains, inside cupboards etc.).
The detector must be installed:
On a wall in a position in which there is always natural air circulation.
In an accessible position to allow easy checks and inspections.