All rights reserved. Reproduction as well as electronic duplication of this user manual, complete or in part, requires the written consent of
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change.
ESERA-Automation, E-Service GmbH 2019
www.esera.de
11233 V1.0 R1.1 Manual
Page 4 of 7
7
Conformity
EN 50090-2-2,
EN 61000-4-2, ESD
EN 61000-4-3, HF
EN 61000-4-4, Burst
EN 61000-4-5, Surge
EN 61000-6-1, Fault-free operation
EN 61000-6-3, Stray radiations
RoHS
8
LED display and button
The module has two LED displays.
Indicator
Designation
LED Function
LED Green
Output 1
- LEDs flash at system start-up
- LED is lit when an output relay is active
- Indicator for power saving mode
LED Green
Output 2
- LEDs flash at system start-up
- LED is lit when an output relay is active
Button
Designation
Button function
1 internal
Output 1 On/Off
Button 1 has two different functions
-
Changeover of relay 1
-
Power saving mode on/off
For details refer to chapter „Power saving mode“
2 internal
Output 2 On/Off
Changeover of relay 2
1 external
Output 1 On/Off
Changeover of relay 1
2 external
Output 2 On/Off
Changeover of relay 2
9
Button and 1-Wire Interfaces
In addition to the buttons on the top side of the module, the module has an external button-interface to connect
two external buttons (make contact). This means, light switches can be connected to the external button interface
to control on/off light commands. For connection regular light switches of all manufacturers can be used.
Within the module, a µ-controller takes over the query of the buttons, the 1-Wire interface and the control of the
relays. Flank control is used to query buttons and 1-Wire component.
The switching status of the relays can be set via the external and internal buttons. Relays can also be set by the
1-Wire Interface. The state of the relay can be read via the 1-wire interface.
External and internal control inputs:
Button interface, external button 1
Button interface, external button 2
Module top side, button 1 internal
Module top side, button 2 internal
1-Wire component, DS2413 channel 0
1-Wire component, DS2413 channel 1
Do not connect any kind of power source to the external button interface! Connecting cables among the module
and the button to other cables should be insulated. In idle mode 5 V direct power can be measured at the
connections of the button interface.
10
Software / Control
The component is being controlled by 1-Wire Commands for the component DS2413. The relay state will be read
out automatically by the 1-Wire Interface. Relays set via pushbutton interface or manual mode can be read back
via the 1-wire interface.
Available 1-Wire commands
Read ROM
33h
64-BIT ROM, RC-FLAG
Match ROM
55h
64-BIT ROM, RC-FLAG
Search ROM
F0h
64-BIT ROM, RC-FLAG
Skip ROM
CCh
RC-FLAG
Read PIO Registers
F0h
Input und Output Status, Bit 0-2 for Channel 0 und 1
Channel Access Write
5Ah
Port Output Latches / Status, Bit 0-2, values greater than 3 are ignored