Art. No. 11233 

 
 
 

User Guide 

Binary Output / Dual Switch Module  

for 1-Wire Bus

 

 
 

 

  Two changeover relays with 10A continuous power rating

 

  Control inputs for button and 1-Wire Bus

 

  LED indicator for activated relays

 

  Switching of direct power and alternative power consumers,

 

e. g. lighting, heating or sockets

 

  DIN rail housing for switchboard assembly  

  Easy software-based control 

  Low space requirement in switchboard 

 

  Easy to assemble

 

  New, with a DS2408 interface 

 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Introduction 

Before you start assembling the 

Dual Switch Module

 and before you take the device into operation, please read 

these assembly and operating instructions carefully to the end, especially the section referring to the safety notes.

 

 

 

Product description 

With the 

Dual Switch Module

 it is possible to connect direct power consumers and alternative power consumers 

with an output of up to 10A continuous power. It is also possible to control motors. 
The 

Dual Switch Module

 can either be controlled directly by an external button or by button on the module top 

side, independent of the 1-Wire interface. For switch operation only 12 V power is required. Thus, a high 
reliability, e.g. for switching of lightings, outlet circuits or other consumers can be reached, even in case of a 
breakdown of a central control / software. 
To operate the switch module we recommend the use of one of our 1-Wire Hub modules. 
 
 
 
 
 
 

 

 

Содержание 11233

Страница 1: ... New with a DS2408 interface 1 Introduction Before you start assembling the Dual Switch Module and before you take the device into operation please read these assembly and operating instructions carefully to the end especially the section referring to the safety notes 2 Product description With the Dual Switch Module it is possible to connect direct power consumers and alternative power consumers ...

Страница 2: ... Wire component DS2413 Dual I O Supply voltage 12VDC 10 Power consumption12V Idle mode no output relay active approx 6mA both output relays are active approx 75mA in normal mode approx 40mA in power saving mode Button interface 2 input for button make contact no external power allowed Connection Screw terminals up to 2 5qmm wire cross section 4 Ambient conditions Temperature operation 0 C up to 50...

Страница 3: ... consent of ESERA Automation or E Service GmbH Errors and technical modification subject to change ESERA Automation E Service GmbH 2019 www esera de 11233 V1 0 R1 1 Manual Page 3 of 7 Art No 11233 6 Connection Example The following example shows 1 Wire Controller or 1 Wire Gateway Dual Digital Output and 8 channel digital input ...

Страница 4: ... button interface to control on off light commands For connection regular light switches of all manufacturers can be used Within the module a µ controller takes over the query of the buttons the 1 Wire interface and the control of the relays Flank control is used to query buttons and 1 Wire component The switching status of the relays can be set via the external and internal buttons Relays can als...

Страница 5: ...e switched to active add up the output values Example Output value 1 2 3 Permitted output values for 1 Wire digital outputs 0 3 Command SET OWD OUTH OWD Number Output Value Example set owd outh 2 3 OWD Number 2 outputs 1 and 2 will be switched to active After switching the output latest status will be output as confirmation 11 3 Data output 1 Wire Controller 1 Wire Gateway For the Dual Switch Modu...

Страница 6: ...e used In case of doubt consultation with experts or the manufacturer of the components used is absolutely necessary For operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be returned without their housing when not functional with an exact error description and the accompanying instructions Without an error description i...

Страница 7: ...le legally protected designations of their respective owners and are hereby recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim any kind on the part of ESERA Automation Andreas Geisler on these designations logos names and trademarks Moreover from their appearance at ESERA Automation webpages ...

Отзывы: