MASTER CLOCK SOFTWARE - Program Descriptions

The ES-102 is shipped with a CD that contains several "Setup" Programs. Some of those programs are discussed
below. All programs are described in the "Readme" file. It is suggested that one refer to the "Readme" file as it may
contain updates issued after this manual was published. This software is also available from our web-site at
"

www.ESE-WEB.com

". The DOS programs described below do not need to be used if the Windows

 programs are

used. For Win 3.1, use the "16 Bit" programs. For Win 95/98/ME/NT/2000, use the "32 Bit" programs. The DOS
programs are in the form of separate command-line utilities. For the Windows versions, run the Setup.exe program.
After the Install Wizard runs, a shortcut to the executable file will appear in your Start Menu.

ESEGPS

This Windows

 program synchronizes the computer system time to the Master Clock time, and provides a control

panel for adjusting various Master Clock functions. This program may be used to reinitialize the receiver if necessary.
This program opens as a "watch" icon in the System Tray. Click on this icon to open the Control Panel applet.

MASTER32

This Windows

 program works with the ASCII time output (Format "A", "0" or "1"). It synchronizes the computer

system time to the Master Clock time. This program opens as a "watch" icon in the System Tray. Click on this icon to
open the Control Panel applet.

MCDOS.EXE

This DOS program will set the System Time and Date of a PC/Compatible computer from an ES-102 GPS Master
Clock when the machine is booted up. The line "MCDOS" should be added to your AUTOEXEC.BAT file. The file
MCDOS.EXE should be placed either in the root directory or where the current PATH can find it.

The program by default is set to use COM1. To set it to a different COM port, add the port number to the command
line:

MCDOS /2

The MCDOS.EXE program may also be invoked from the DOS prompt to set the time whenever desired. If you are
using the optional serial port command described above, you can make running the program easier by creating a
batch file to run the program:

COPY CON:T.BAT <enter>
MCDOS /2 <enter>
F6 (the function key) <enter>

Now, just typing T <enter> will set the time.

GPSINI.EXE

This DOS program is used to initialize the Time Zone, Time Delay and Cable Delay Compensation values. The Time
Delay factor is set to zero, and the Cable Compensation is set for 19 feet. Running the program will print full
instructions on screen for setting the time zone.

GPSHIFT(x).EXE

These DOS programs are used set the ES-102 to provide an advanced or delayed time output. This can be useful in
TV network situations to compensate for video satellite delays. The time is adjustable from 0 to +/- 400 milliseconds,
in increments of 1 millisecond. Determine which COM port you have available and use GPSHIFT1.EXE for COM1:
and GPSHIFT2.EXE for COM2:. To set a 1/4 second delay using COM1:, for example, type GPSHIFT1-250 then hit
the ENTER key.

GPSCBL(x).EXE

These DOS programs are used to compensate for antenna cable delay, adjustable from 0 - 22215 feet. Determine
which COM port you have available and use GPSCBL1.EXE for COM1: and GPSCBL2.EXE for COM2:. To
compensate the unit for 200 feet using COM1:, for example, type GPSCBL1 200 then hit the ENTER key.

NOTE:

All of these settings are remembered by the ES-102, even if powered down with the battery off.

GPSTIME.EXE

This DOS program is used to set the Time and Date of the unit in the absence of a satellite signal.

Содержание ES-102

Страница 1: ... periods without power The battery is capable of maintaining the settings for up to four years If the receiver needs re initialization refer to the master clock software program descriptions on page 11 STANDARD FEATURES Power Supply The ES 102 is equipped with an internal Power Supply The Power Supply requires 117 VAC via the 3 wire line cord Display The front panel contains a single green LED tha...

Страница 2: ...y of applications One such application allows the 1PPS to drive an Impulse Driver ES 165 or ES 162A which in turn can drive Analog Impulse Clocks ES 168 or ES 162S Battery The ES 102 has a lithium coin cell battery that maintains certain receiver configuration settings during power outages storage or shipment The battery is capable of maintaining these settings for up to four years All outputs how...

Страница 3: ...the LED does not light Option 45ηS is required The Option K system functions independently from the rest of the clock although it receives its input from the same GPS receiver as the clock system When first powered up the receiver searches for satellites When it locks on to at least one the GPS Lock LED indicates a locked condition by lighting solidly The 10 MHz Lock LED begins flashing after a de...

Страница 4: ...rs Displays if ordered are blank during a power outage If continuous displays during power outages are required a UPS Uninterruptable Power Supply is suggested Note Turn off the battery during shipment or any extended periods of time without main power DC The ES 102 can be ordered from the factory to operate exclusively from a DC source The voltage applied must be in the range from 12 VDC to 36 VD...

Страница 5: ...tion DRIFT 33mS Day POWER 117 VAC 50 60 Hz 15 Watts typical MECHANICAL Rack Mount Enclosure 1 75 H x 19 W x 9 5 D plus connectors OPTION K 10 MHz Sine wave BNC 4 Vpp into 50 ohms adjustable 0 5V 1 KHz Square wave BNC 5 Vpp CMOS TTL 1 PPS 50 duty cycle DB 9 pin 5 5 Vpp CMOS TTL 2 µS of GPS when 10 MHz lock LED is solid REAR PANEL DB 9 CONNECTOR PIN DESIGNATIONS Pin Function 1 12 VDC 36 VDC Input op...

Страница 6: ...XTRA CABLE RG 58 LA 12FN LA 12FN LA 12FN LA 12FN LA 12FN ES 102 ES AB1A GPS Antenna 16 5 100 100 100 100 100 2 Figure 3 ANTENNA With 5 LA 12FN And 500 Of EXTRA CABLE RG 8 With ES AB1A TEMPLATE FOR ANTENNA MOUNTING PLATE Figure 1 Note The Antenna Mounting Plate can also be used as a Template ...

Страница 7: ... using the template provided on page 6 through the deck plane where you are mounting the antenna 3 Press into each hole a plastic anchor until the top of the anchor is flush with the deck plane 4 Drill a 5 8 hole for the antenna connector cable slightly below where the antenna is to be mounted 5 Route the antenna connector cable through the 5 8 hole and then fasten the Antenna to the deck plane us...

Страница 8: ...e to contact the ESE factory for assistance Also please read the section below which discusses the tests performed at ESE CABLING SUGGESTIONS ALTERNATIVES Method 1 low loss cable Several types of low loss coax cable are available including RG 8 and RG 213 Using any of these types of cable may allow up to 300 of additional cable to be added to the 16 5 supplied with the antenna Both RG 8 and RG 213...

Страница 9: ...B1A power divider and two 2 LA 12F with 100 of RG 58 cable attached to each 216 5 total permitted the clock to lock on in a nominal amount of time Adding a third LA 12F with 75 of RG 58 cable did not impair the clock s performance however increasing the 75 to 100 did impair the clock s performance Test 4 Using an ES AB1A power divider and four 4 LA 12F with 75 of RG 58 cable attached to each 316 5...

Страница 10: ...y decrease and excessive cable length may cause undesirable results Application Note 2 All ESE tests were conducted using RG 58 coax cable According to several manufacturers of low loss cable the signal loss attributable to cable length can be reduced with the use of low loss cable According to the RG 8 and RG 213 cable specifications when compared to RG 58 cable lengths may be doubled or more wit...

Страница 11: ...ld be placed either in the root directory or where the current PATH can find it The program by default is set to use COM1 To set it to a different COM port add the port number to the command line MCDOS 2 The MCDOS EXE program may also be invoked from the DOS prompt to set the time whenever desired If you are using the optional serial port command described above you can make running the program ea...

Страница 12: ... 102 GPS MASTER CLOCK POWER FUSE BATTERY SMPTE EBU RS 232C 1PPS ON OFF TC89 TC90 VIDEO IN ANTENNA ES 102 GPS MASTER CLOCK The unit is shown with Option K 10 MHz LOCK OUTPUT OUTPUT OUTPUT INPUT OUTPUT OUTPUT INPUT 1 KHz OPTIONAL 10 MHz ...

Страница 13: ...8 RESISTOR 120K 1 4 W 1 R7 RESISTOR 470K 1 4 W 1 R2 RESISTOR 680K 1 4 W 1 R6 RESISTOR 1 MEGOHM 1 4 W 1 R5 RESISTOR 2 2 MEGOHM 1 4W 1 R24 RESISTOR 1K OHM mini pot 1 R12 RESISTOR 50K OHM mini pot 1 C16 CERAMIC CAPACITOR 47pf 50v Cer K 1 C15 CERAMIC CAPACITOR 002uf 50v Cer Z 7 C7 C12 C17 CERAMIC CAPACITOR 1uf 50v Cer Z 1 C18 TANTALUM CAPACITOR 22uF TANTALUM 2 C13 C14 ELECTROLYTIC CAPACITOR 100uf 25v ...

Страница 14: ...L POWER PLUG UL PWR PLUG 1 45 nS M12 TIMING RECEIVER P273T12T17 IF COMPONENT REMOVAL IS REQUIRED WE RECOMMEND REMOVING ALL SOLDER USING A 35W OR SMALLER SOLDERING IRON AND SOLDER WICK TO PREVENT DAMAGE TO THE PRINTED CIRCUIT BOARD ALL INFORMATION CONTAINED IN THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE CHASSIS COMPONENTS OPTIONAL COMPONENTS ES 102 PARTS LIST CONTINUED NOTE THIS EQUIPMENT HAS B...

Страница 15: ...14 1 Q1 TRANSISTOR PN2222 1 HEAT SINK 300 TO220 HEAT SINK 1 8 POSITION DIP SWITCH 8 POS DIP SWITCH 1 SOCKET 16 PIN DIP SOCKET 1 SOCKET 18 PIN DIP SOCKET 1 SOCKET 40 PIN DIP SOCKET 2 BRACKET 616 L BRACKET 3 LTD 6840Y LED DISPLAY 1 PCB ES USS 1 PCB ES UCT2 DISPLAY QTY DESIGNATION DESCRIPTION PART NUMBER 2 T1 T2 TRANSFORMER P6465 QTY DESIGNATION DESCRIPTION PART NUMBER 1 DC DC DC CONVERTER 1505D20UR ...

Страница 16: ...OTENTIOMETER 1K OHM mini pot 1 C21 CERAMIC CAPACITOR 47pf 50v Cer K 1 C15 CERAMIC CAPACITOR 01uf 50v Cer Z 13 C1 C3 C6 C8 C14 C28 CERAMIC CAPACITOR 1uf 50v Cer Z 2 C22 C23 POLY FILM CAPACITOR 4 7uF POLY FILM 100V 1 C29 ELECTROLYTIC CAPACITOR 10uf 16v LL R El 1 C2 ELECTROLYTIC CAPACITOR 1000uf 16v R El 1 C20 VARIABLE CAPACITOR 5 30 PF TRIMM 5MM V 1 D2 LED Green LED T 1 3 4 1 D3 DIODE 1N4740 1 L1 IN...

Страница 17: ...Page 17 ...

Страница 18: ...Page 18 ...

Страница 19: ...Page 19 ...

Страница 20: ...Page 20 ...

Страница 21: ...Page 21 ...

Страница 22: ...Page 22 ...

Отзывы: