background image

142 SIERRA ST., EL SEGUNDO, CA  90245  USA

 

(310)322-2136   FAX (310)322-8127

 www.ESE-WEB.com

Page 1 of 22

ES-102  GPS BASED

TIME CODE GENERATOR / MASTER CLOCK

OPERATION AND MAINTENANCE MANUAL

The ES-102 is a GPS Master Clock/Time Code Generator. The unit receives accurate time and date information from
Global Positioning System satellites and supplies this data to the user in the form of four (4) different types of time
code (SMPTE/EBU, ASCII, TC89 and TC90) and a front panel six-digit display (.56” yellow LEDs). Two (2) One Pulse
Per Second outputs and a GPS “Lock” output are also available. A twelve-channel receiver is employed that is
capable of tracking up to twelve (12) satellites simultaneously, although reception of only one is required for time data
to be output.

Several options are available that allow the unit to meet most any requirement asked from a Master Clock or Time
Code Generator. These options are described in the “OPTIONS” section.

INSTALLATION & OPERATION

The basic installation of the ES-102 is nearly as simple as connecting the Antenna Cable and 117 VAC to the unit,
and allowing the unit to "lock" onto GPS. However, after any "bench" testing is complete, the most important concern
is to mount the Antenna and route the cable according to the instructions provided on page 7.

All other connections between the ES-102 and other equipment should be made by a qualified technician or engineer.
The technician or engineer should be familiar with each piece of equipment being interfaced with the ES-102. Please
refer to the descriptions and specifications for details concerning the various Standard Features, Setup Features and
Options. Consult the manufacturer of the equipment or the ESE factory if assistance is required.

A lithium coin cell battery maintains the settings of the GPS receiver during periods without power. The battery is
capable of maintaining the settings for up to four years. If the receiver needs re-initialization, refer to the master clock
software program descriptions on page 11.

STANDARD FEATURES

Power Supply

The ES-102 is equipped with an internal Power Supply. The Power Supply requires 117 VAC via the 3-wire line cord.

Display

The front-panel contains a single green LED that indicates if the unit is "Locked" to GPS. When locked to GPS, the
LED remains lit. Prior to lock or when lock is lost, the LED blinks at a 1 Hz rate. The ES-102 also has a six-digit .56”
high yellow LED display.

Outputs

The rear-panel of the ES-102 provides access to the time codes, 1PPS and GPS Lock outputs via XLR, BNC and
DB-9 connectors. Please refer to the "Rear Panel DB-9 Connector Pin Designations" and "Specifications" for more
details.

EBU

: The ES-102 can have an EBU Time Code output specified. The EBU Time Code Output is accessible

via an XLR connector. Accuracy of the EBU is +/- 400 mS and can be synchronized to a video source
via the "Video In" BNC connector. The EBU time code is automatically “re-synched” to GPS at
2:00:00 AM. EBU (European Broadcasting Union) is used predominantly in Europe in the TV, Cable
and Video industries.

SMPTE

: The ES-102 can have a SMPTE Time Code output specified. The SMPTE Time Code Output is

accessible via an XLR connector. Accuracy of the SMPTE is +/- 400 mS and can be synchronized to
a video source via the "Video In" BNC connector. The SMPTE time code is automatically “re-
synched” to GPS at 2:00:00 AM. SMPTE (Society of Motion Picture and Television Engineers) is
used predominantly in the TV, Cable and Video industries. The SMPTE User Bits are, from high to
low, as follows: 1OY-X-Y-X-10M/10D-M-D-X. When Julian Day of Year is used, the SMPTE User Bits
are as follows: X-X-X-X-X-100D-10D-D.

Drop Frame

:  Unless otherwise specified, the unit is set to provide "Drop Frame" SMPTE Time Code. If

non-Drop Frame SMPTE is desired, turn “ON” the “NDF” DIP switch (switch #7 on the
ES-101 logic board).

Содержание ES-102

Страница 1: ... periods without power The battery is capable of maintaining the settings for up to four years If the receiver needs re initialization refer to the master clock software program descriptions on page 11 STANDARD FEATURES Power Supply The ES 102 is equipped with an internal Power Supply The Power Supply requires 117 VAC via the 3 wire line cord Display The front panel contains a single green LED tha...

Страница 2: ...y of applications One such application allows the 1PPS to drive an Impulse Driver ES 165 or ES 162A which in turn can drive Analog Impulse Clocks ES 168 or ES 162S Battery The ES 102 has a lithium coin cell battery that maintains certain receiver configuration settings during power outages storage or shipment The battery is capable of maintaining these settings for up to four years All outputs how...

Страница 3: ...the LED does not light Option 45ηS is required The Option K system functions independently from the rest of the clock although it receives its input from the same GPS receiver as the clock system When first powered up the receiver searches for satellites When it locks on to at least one the GPS Lock LED indicates a locked condition by lighting solidly The 10 MHz Lock LED begins flashing after a de...

Страница 4: ...rs Displays if ordered are blank during a power outage If continuous displays during power outages are required a UPS Uninterruptable Power Supply is suggested Note Turn off the battery during shipment or any extended periods of time without main power DC The ES 102 can be ordered from the factory to operate exclusively from a DC source The voltage applied must be in the range from 12 VDC to 36 VD...

Страница 5: ...tion DRIFT 33mS Day POWER 117 VAC 50 60 Hz 15 Watts typical MECHANICAL Rack Mount Enclosure 1 75 H x 19 W x 9 5 D plus connectors OPTION K 10 MHz Sine wave BNC 4 Vpp into 50 ohms adjustable 0 5V 1 KHz Square wave BNC 5 Vpp CMOS TTL 1 PPS 50 duty cycle DB 9 pin 5 5 Vpp CMOS TTL 2 µS of GPS when 10 MHz lock LED is solid REAR PANEL DB 9 CONNECTOR PIN DESIGNATIONS Pin Function 1 12 VDC 36 VDC Input op...

Страница 6: ...XTRA CABLE RG 58 LA 12FN LA 12FN LA 12FN LA 12FN LA 12FN ES 102 ES AB1A GPS Antenna 16 5 100 100 100 100 100 2 Figure 3 ANTENNA With 5 LA 12FN And 500 Of EXTRA CABLE RG 8 With ES AB1A TEMPLATE FOR ANTENNA MOUNTING PLATE Figure 1 Note The Antenna Mounting Plate can also be used as a Template ...

Страница 7: ... using the template provided on page 6 through the deck plane where you are mounting the antenna 3 Press into each hole a plastic anchor until the top of the anchor is flush with the deck plane 4 Drill a 5 8 hole for the antenna connector cable slightly below where the antenna is to be mounted 5 Route the antenna connector cable through the 5 8 hole and then fasten the Antenna to the deck plane us...

Страница 8: ...e to contact the ESE factory for assistance Also please read the section below which discusses the tests performed at ESE CABLING SUGGESTIONS ALTERNATIVES Method 1 low loss cable Several types of low loss coax cable are available including RG 8 and RG 213 Using any of these types of cable may allow up to 300 of additional cable to be added to the 16 5 supplied with the antenna Both RG 8 and RG 213...

Страница 9: ...B1A power divider and two 2 LA 12F with 100 of RG 58 cable attached to each 216 5 total permitted the clock to lock on in a nominal amount of time Adding a third LA 12F with 75 of RG 58 cable did not impair the clock s performance however increasing the 75 to 100 did impair the clock s performance Test 4 Using an ES AB1A power divider and four 4 LA 12F with 75 of RG 58 cable attached to each 316 5...

Страница 10: ...y decrease and excessive cable length may cause undesirable results Application Note 2 All ESE tests were conducted using RG 58 coax cable According to several manufacturers of low loss cable the signal loss attributable to cable length can be reduced with the use of low loss cable According to the RG 8 and RG 213 cable specifications when compared to RG 58 cable lengths may be doubled or more wit...

Страница 11: ...ld be placed either in the root directory or where the current PATH can find it The program by default is set to use COM1 To set it to a different COM port add the port number to the command line MCDOS 2 The MCDOS EXE program may also be invoked from the DOS prompt to set the time whenever desired If you are using the optional serial port command described above you can make running the program ea...

Страница 12: ... 102 GPS MASTER CLOCK POWER FUSE BATTERY SMPTE EBU RS 232C 1PPS ON OFF TC89 TC90 VIDEO IN ANTENNA ES 102 GPS MASTER CLOCK The unit is shown with Option K 10 MHz LOCK OUTPUT OUTPUT OUTPUT INPUT OUTPUT OUTPUT INPUT 1 KHz OPTIONAL 10 MHz ...

Страница 13: ...8 RESISTOR 120K 1 4 W 1 R7 RESISTOR 470K 1 4 W 1 R2 RESISTOR 680K 1 4 W 1 R6 RESISTOR 1 MEGOHM 1 4 W 1 R5 RESISTOR 2 2 MEGOHM 1 4W 1 R24 RESISTOR 1K OHM mini pot 1 R12 RESISTOR 50K OHM mini pot 1 C16 CERAMIC CAPACITOR 47pf 50v Cer K 1 C15 CERAMIC CAPACITOR 002uf 50v Cer Z 7 C7 C12 C17 CERAMIC CAPACITOR 1uf 50v Cer Z 1 C18 TANTALUM CAPACITOR 22uF TANTALUM 2 C13 C14 ELECTROLYTIC CAPACITOR 100uf 25v ...

Страница 14: ...L POWER PLUG UL PWR PLUG 1 45 nS M12 TIMING RECEIVER P273T12T17 IF COMPONENT REMOVAL IS REQUIRED WE RECOMMEND REMOVING ALL SOLDER USING A 35W OR SMALLER SOLDERING IRON AND SOLDER WICK TO PREVENT DAMAGE TO THE PRINTED CIRCUIT BOARD ALL INFORMATION CONTAINED IN THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE CHASSIS COMPONENTS OPTIONAL COMPONENTS ES 102 PARTS LIST CONTINUED NOTE THIS EQUIPMENT HAS B...

Страница 15: ...14 1 Q1 TRANSISTOR PN2222 1 HEAT SINK 300 TO220 HEAT SINK 1 8 POSITION DIP SWITCH 8 POS DIP SWITCH 1 SOCKET 16 PIN DIP SOCKET 1 SOCKET 18 PIN DIP SOCKET 1 SOCKET 40 PIN DIP SOCKET 2 BRACKET 616 L BRACKET 3 LTD 6840Y LED DISPLAY 1 PCB ES USS 1 PCB ES UCT2 DISPLAY QTY DESIGNATION DESCRIPTION PART NUMBER 2 T1 T2 TRANSFORMER P6465 QTY DESIGNATION DESCRIPTION PART NUMBER 1 DC DC DC CONVERTER 1505D20UR ...

Страница 16: ...OTENTIOMETER 1K OHM mini pot 1 C21 CERAMIC CAPACITOR 47pf 50v Cer K 1 C15 CERAMIC CAPACITOR 01uf 50v Cer Z 13 C1 C3 C6 C8 C14 C28 CERAMIC CAPACITOR 1uf 50v Cer Z 2 C22 C23 POLY FILM CAPACITOR 4 7uF POLY FILM 100V 1 C29 ELECTROLYTIC CAPACITOR 10uf 16v LL R El 1 C2 ELECTROLYTIC CAPACITOR 1000uf 16v R El 1 C20 VARIABLE CAPACITOR 5 30 PF TRIMM 5MM V 1 D2 LED Green LED T 1 3 4 1 D3 DIODE 1N4740 1 L1 IN...