background image

Order Information

          Hardware Manual • Doc. No.: V.1915.21 / Rev. 1.0 

VME-PMC-CADDY/2

Page 42 of  43

7. Order Information

Type

Properties

Order No.

VME-PMC-CADDY/2

VMEbus base board for two single PMC modules,
standard temperature range: 0 

/

C...+50 

/

C,

P2-pin assignment acc. to  to VITA 35 (P4V2-
64ac, P4V0-64), (no interconnection between
PMC modules), no XMC, 3.3V supply for PMC
fed from VMEbus

V.1915.02

VME-PMC-CADDY/2-T

as V.1915.02, but for extended temperature 
range: - 40 

/

C ...+85 

/

C

V.1915.03

VME-PMC-CADDY/2-32P2

VMEbus base board for two single PMC modules,
P2-pin assignment acc. to IEEE Std 1386-2001,
Table 8 (interconnection between 16 pins of the
PMC-modules), no XMC, 3.3V supply for PMC
fed from VMEbus

V.1915.11

VME-PMC-CADDY/2-T-32P2

as V.1915.11, but for extended temperature 
range: - 40 

/

C...+85 

/

C

V.1915.13

VME-PMC-CADDY/2-CC

as V.1915.02, but  conduction cooled,
extended temperature range: - 40 

/

C...+85 

/

C

V.1916.02

VME-PMC-CADDY/2-CC-32P2

as V.1915.11, but conduction cooled,
extended temperature range: - 40 

/

C...+85 

/

C

V.1916.11

Accessories

VME-PMC-CPU/Cable

Adapter cable for serial interface 1 (RS232) from
har-link10 to DSUB9 socket, length: 1.0 m
For details see page 24

V.1917.25

VME-PMC-CPU/Cable-Y

Adapter cable for serial interface 1 and 2 (RS232),
Y-junction from har-link10 to 2x DSUB9 socket,
length: 1.5m
For details see page 25

V.1917.26

Software 

VME-PMC-CADDY/2-VxWorks-LIB

VxWorks Library

V.1915.58

For detailed information about the driver availability for your operating system, please contact our sales
team.

Table 11: Order information

Содержание VME-PMC-CADDY/2

Страница 1: ...0 Page 1 of 43 esd electronic system design gmbh Vahrenwalder Str 207 30165 Hannover Germany http www esd eu Phone 49 0 511 3 72 98 0 Fax 49 0 511 3 72 98 68 VME PMC CADDY 2 VME Carrier Board for PMC...

Страница 2: ...h is part of a product of esd gmbh esd does not convey to the purchaser of the product described herein any license under the patent rights of esd gmbh nor the rights of others esd electronic system d...

Страница 3: ...wpd Date of print 2012 02 01 PCB version VME PMC CADDY 2 Rev 2 1 Changes in the chapters The changes in the document listed below affect changes in the hardware and firmware as well as changes in the...

Страница 4: ...electric circuits into operation according to the applicable national standards of safety engineering Intended Use The intended use of the VME PMC CADDY 2 module is the operation as a carrier board i...

Страница 5: ...940 23 5 2 Adapter Cable VME PMC CPU Cable 24 5 3 Adapter Cable VME PMC CPU Cable Y 25 5 4 VMEbus P1 26 5 5 Standard Assignment of I O Signals 27 5 5 1 Standard Assignment VMEbus P2 According to VITA...

Страница 6: ...i148 is designed in a way that the board can either operate as slave or as master on the VMEbus If the board operates as master it supports a 4 level arbiter The VMEbus interrupt can be applied to any...

Страница 7: ...o different I O pin assignments In the Standard configuration each of the I O pins of the PMC slot 1 J14 is connected to exactly one pin of the VMEbus connector P2 according to VITA 35 P4V2 64ac and e...

Страница 8: ...heat sinks for heat dissipation in conduction cooled systems The slots of the PMC modules are conduction cooled PMC modules As a result of the heat sinks the front panel and with it the 10 pin har li...

Страница 9: ...re range Standard 0 50 C order no V 1915 02 11 Extended temperature range 40 85 C order no V 1915 03 13 Conduction cooled 40 85 C order no V 1916 02 11 Humidity max 90 non condensing Connectors P1 P2...

Страница 10: ...5 ca 1 0 A 3 3 V 5 ca 400 mA 12V 5 only to PMC slots 12V 5 only to PMC slots Table 1 General technical data 1 4 2 Serial Interfaces Number 2 Control UART im MPC8349 Signals to X1940 RxD TxD RTS CTS fo...

Страница 11: ...y voltage In the standard placement all PMC power supply voltages are directly suppled via the VMEbus connectors 3 3 V max 1 5 A current consumption per PMC slot 3 3 V AUX for both PMC slots together...

Страница 12: ...0 A current consumption U 12V 12 V 5 max 1 0 A current consumption U 12V 12 V 5 max 1 0 A current consumption Note The maximum permissible sum of the power consumption of the XMC module corresponds t...

Страница 13: ...Front Panel and LEDs VME PMC CADDY 2 Hardware Manual Doc No V 1915 21 Rev 1 0 Page 13 of 43 2 Front Panel and LEDs Figure 3 Front of the VME PMC CADDY 2...

Страница 14: ...Front Panel and LEDs Hardware Manual Doc No V 1915 21 Rev 1 0 VME PMC CADDY 2 Page 14 of 43 Figure 4 Front of the conduction cooled version VME PMC CADDY 2 CC...

Страница 15: ...DDY 2 triggers an interrupt on the VMEbus F FAIL red VME PMC CADDY 2 triggers FAIL on VMEbus E BERR red VME PMC CADDY 2 triggers Bus Error on VMEbus Table 4 Indication of the LEDs 2 2 Reset Button The...

Страница 16: ...figuration Hardware Manual Doc No V 1915 21 Rev 1 0 VME PMC CADDY 2 Page 16 of 43 3 PCB View with Coding Switches and Connectors Figure 5 Position of the coding switches and connectors on VME PMC CADD...

Страница 17: ...scription SW600 8 OFF 1 SFAILEN Control Bit Reset Value VMEbus Power Up Options 7 OFF 1 SFAILAI Control Bit Auto Clear 6 ON 0 Auto Slot ID Enable 5 ON 0 Geographical Slot ID Enable 4 OFF 1 not used 3...

Страница 18: ...on Default setting 8 SFAILEN Control Bit Reset Value VMEbus Power Up Optionen OFF 7 SFAILAI Control Bit Auto Clear OFF 6 Auto Slot ID Enable ON 5 Geographical Slot ID Enable ON 4 not used these coding...

Страница 19: ...1 Function SCONEN SCONDIS OFF OFF Auto SCON automatic activation of the system controller depending of signal VBG3IN ON OFF System controller activated OFF ON System controller deactivated ON ON not a...

Страница 20: ...gnals VD 0 to VD 3 are evaluated Coding switch contact VMEbus data bit Power up option Description 8 VD 0 SFAILEN_RV SFAILEN Control Bit Reset Value 7 VD 1 SFAILAI_AC SFAILAI Control Bit Auto Clear 5...

Страница 21: ...t Name Description Default 4 P MONARCH 1 Monarch Non Monarch PMC module 1 OFF Non Monarch ON Monarch OFF 3 P MONARCH 2 Monarch Non Monarch PMC module 2 OFF Non Monarch ON Monarch OFF 2 P M66EN Clock r...

Страница 22: ...PMC CADDY 2 Address range Assignment 0x00000000 0x07ffffff DDR2 RAM 72 bit data width 0x80000000 0x8fffffff PCI Memory Space prefetchable 0x90000000 0x9fffffff PCI Memory Space 0xe0000000 0xe00fffff...

Страница 23: ...GND 5V z Shield Shield Signal description TXSx RXSx RTSSx CTSSx Data and control signals of the serial interfaces 1 and 2 x 1 2 The signal direction is seen from the VME PMC CADDY 2 i e TXSx output A...

Страница 24: ...link to 9 pin DSUB order No V 1917 25 is available for the connection of the serial interface 1 Pin Position DSUB9 Pin Assignment DSUB9 Signal direction har link Pin Signal Pin 1 2 TXS1 a1 3 RXS1 a2...

Страница 25: ...nnection of the serial interfaces 1 and 2 Pin Position in the DSUB9 Socket Pin Assignment DSUB9 1 Signal direction har link DSUB9 2 Signal direction har link Pin Signal Pin Pin Signal Pin 1 1 2 TXS1 a...

Страница 26: ...A07 A06 A05 A04 A03 A02 A01 12 V 5 V BBSY BCLR ACFAIL BG0IN BG0OUT BG1IN BG1OUT BG2IN BG2OUT BG3IN BG3OUT BR0 BR1 BR2 BR3 AM0 AM1 AM2 AM3 GND GND IRQ7 IRQ6 IRQ5 IRQ4 IRQ3 IRQ2 IRQ1 5V STBY 5 V D08 D09...

Страница 27: ...O114 I O116 I O118 I O120 I O122 I O124 I O126 I O128 I O130 I O132 I O134 I O136 I O138 I O140 I O142 I O144 I O146 I O148 I O150 I O152 I O154 I O156 I O158 I O160 I O162 I O164 5 V GND BRETRY A24...

Страница 28: ...26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 I O102 I O104 I O106 I O108 I O110 I O112 I O114 I O1...

Страница 29: ...O233 I O234 I O235 14 GND I O236 I O237 I O238 I O239 I O240 15 GND I O241 I O242 I O243 I O244 I O245 16 GND I O246 I O247 I O248 I O249 I O250 17 GND I O251 I O252 I O253 I O254 I O255 18 GND I O25...

Страница 30: ...c6 c7 c8 c9 c10 c11 c12 c13 c14 c15 c16 c17 c18 c19 c20 c21 c22 c23 c24 c25 c26 c27 c28 c29 c30 c31 c32 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 2 4...

Страница 31: ...5 b5 e6 c6 a6 d7 b7 e8 c8 a8 d12 b12 e13 c13 a13 d14 b14 e15 c15 a15 d16 b16 e17 c17 a17 d18 b18 e19 c19 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 2 4...

Страница 32: ...O262 I O132 I O264 I O134 I O136 I O138 I O140 I O142 I O144 I O146 I O148 I O150 I O152 I O154 I O156 I O158 I O160 I O162 I O164 5 V GND BRETRY A24 A25 A26 A27 A28 A29 A30 A31 GND 5 V D16 D17 D18 D1...

Страница 33: ...34 I O104 I O236 I O106 I O238 I O108 I O240 I O110 I O242 I O112 I O244 I O114 I O246 I O116 I O248 I O118 I O250 I O120 I O252 I O122 I O254 I O124 I O256 I O126 I O258 I O128 I O260 I O130 I O262 I...

Страница 34: ...O241 I O110 I O242 I O111 I O243 I O112 I O244 I O113 I O245 16 GND I O114 I O246 I O115 I O247 I O116 I O248 I O117 I O249 I O118 I O250 17 GND I O119 I O251 I O120 I O252 I O121 I O253 I O122 I O25...

Страница 35: ...21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 34 36 38 40 42 44 46 48 50 52 54 56 58 60...

Страница 36: ...3 c13 a13 d14 b14 e15 c15 a15 d16 b16 e17 c17 a17 d18 b18 e19 c19 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63...

Страница 37: ...ND I O244 GND I O246 GND I O102 I O104 I O106 I O108 I O110 I O112 I O114 I O116 I O118 I O120 I O122 I O124 I O126 I O128 I O130 I O132 I O134 I O136 I O138 I O140 I O142 I O144 I O146 I O148 I O150...

Страница 38: ...O249 I O261 I O263 d1 d2 z3 d5 d6 z7 d9 d10 z11 d13 d14 z15 d17 d18 z19 d21 d22 z23 d25 d26 z27 d29 d30 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 2 4...

Страница 39: ...3V PER_1_P PER_1_N VPWR 2 GND GND PCI TRST GND GND PORST 3 PER_2_P PER_2_N 3 3V PER_3_P PWER_3_N VPWR 4 GND GND PCI TCK GND GND XMC_RSTO 5 3 3V VPWR 6 GND GND PCI TMS GND GND 12V 7 3 3V VPWR 8 GND GN...

Страница 40: ...riggered by the XMC card XMC_BIST This pin is not connected on the board XMC_PRSNT PMC module detection signal IIC2_SDA IIC2_SCL I C data and clock signal IPMI support REFCLK_1_P REFCLK_1_N 100 MHz PC...

Страница 41: ...1915 21 Rev 1 0 Page 41 of 43 6 References 1 Tsi148 PCI X to VME Bus Bridge User Manual Tundra Semiconductor Corporation referenced document version 80A3020_MA001_10 April 2008 document source http w...

Страница 42: ...ly for PMC fed from VMEbus V 1915 11 VME PMC CADDY 2 T 32P2 as V 1915 11 but for extended temperature range 40 C 85 C V 1915 13 VME PMC CADDY 2 CC as V 1915 02 but conduction cooled extended temperatu...

Страница 43: ...ng table Please download the manuals as PDF documents from our esd website www esd eu for free Manuals Order No VME PMC CADDY 2 MD Hardware manual in German V 1915 20 VME PMC CADDY 2 ME Hardware manua...