Special Designs with CPCI-CAN-ISO11898 Add-On
CPCI-405
Hardware-Manual • Doc.-No.: I.2306.21 / Rev. 3.5
Page 43 of 57
P200
L
B
1
0
2
L
B
1
0
3
L
B
1
0
1
L
B
1
0
0
5.3.4 Solder Bridges for the Configuration of the Serial Interface SER1
The serial interface SER1 can be configured with the solder bridges LB100 - LB103.
Fig. 5.3.5: Position of the solder bridges on the board (detail drawing)
Configuration of the serial interface SER1 with the solder bridges LB100-LB102:
solder
bridge
RS-232
interface
RS-422
interface
RS-485
interface
LB100
closed
open
open
LB101
closed
closed
open
LB102
open
closed
open
Table 5.3.1: Configuration of the serial interface SER1
With the solder bridge LB103 the FAST control pin can be set. The FAST control pin is used to select
the slew-rate limiting of the RS-232 transmitters and the RS-485/422 driver. With the solder bridge
LB103 (FAST unasserted), the RS-232 transmitters and the RS-485/-422 driver are slew-rate limited
to reduce disturbances by electromagnetic impulses (EMI).
For further information, please refer to the datasheet of the serial driver MAX3160: www.maxim.de