Communication Profile Area
CAN-Control-I/O
CANopen Software Manual Rev. 1.1
9
2.3.3 Manufacturer Status Register 1002
h
INDEX
1002
h
Name
manufacturer status register
Data Type
unsigned32
Default Value
n.a.
The bits of the status register are assigned as represented below:
Register-Bit
(Assembler)
Description
Level Assignment
D31 ... D8
This bits are reserved for future use.
0
reserved, may be returned as ‘0’ or ‘1’
1
D7
New on Bus
0
reserved, may be returned as ‘0’ or ‘1’
1
D6
Default wake up
0
normal start
1
module is started with default parameters
D5
I²C busy
0
no access to EEPROM
1
local SW accesses I²C-EEPROM
D4
guard_error
0
no error
1
guard_error (heartbeat-consumer-error)
D3
I²C-Error
0
no I²C-error
1
I²C-error
D2
Error on CAN
0
no CAN-bus error detected
1
CAN-bus error
D1
Suspend-Bit
0
module is in state ‘operational’
1
module is in state ‘preoperational’ or
‘stopped’
D0
Power-Up-Reset
0
last reset is not generated by power-up
1
last reset is generated by power-up
Notes:
- Bits D31...D24 are always read as ‘01
h
’.
- Bits D23...D16 return the actual setting at jumper J220 (ref. hardware manual [1]). This setting is
determined for the hardware bit-rate setting after restart.
- Bits D15...D8 return the actual setting of the codiung switch SW220 (ref. hardware manual [1]).This
setting is determined for the hardware Node-ID setting after restart.
Содержание C.2071.01
Страница 1: ...CAN Control I O Hardware Manual Rev 1 3 CAN Control I O Hardware Manual to product C 2071 xx...
Страница 5: ...CAN Control I O Hardware Manual Rev 1 3 2 This page is intentionally left blank...
Страница 13: ...CAN Control I O Hardware Manual Rev 1 3 10 This page is intentionally left blank...
Страница 27: ...CAN Control I O Hardware Manual Rev 1 3 24...
Страница 28: ...CAN Control I O Software Rev 1 1 CAN Control I O Manual of the Module Specific Software...
Страница 32: ...CAN Control I O Software Rev 1 1 i 2...
Страница 38: ...CAN Control I O Software Rev 1 1 1 6...
Страница 48: ...CAN Control I O Software Rev 1 1 2 10...