![ESD C.2046.02 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/esd/c-2046-02/c-2046-02_hardware-manual_2426428008.webp)
Overview
1. Overview
1.1 Description of the CAN-PCI104/200
Figure 1:
Block circuit diagram of the CAN-PCI104/200
The CAN-PCI104/200-board offers one or two CAN interfaces for the PCI-104 bus or PC/104-Plus
bus. Up to 4 CAN-PCI104/200-modules can be operated in a stack. Thus up to 8 CAN interfaces
are available.
The module can be operated in PCI-104 systems with 3.3 V or 5 V signalling voltage.
The ISO 11898-2- compliant CAN interface allows a maximum data transfer rate of 1 Mbit/s.
Among other properties of the interface the bit rate can be parameterized by software.
The CAN-interface is electrically isolated by a magnetic high speed data coupler and a DC/DC-
converter.
Software drivers for many operating systems as Windows and Linux are available. Real-time
operating systems as for example QNX are supported as well.
Page 8 of 29
Hardware Manual • Doc. No.: C.2046.21 / Rev. 1.1
CAN-PCI104/200
+5 V=
+5 V=
+5 V=
+5 V=
C
A
N
B
U
S
CAN
CAN
PCI Bridge
PCI9030
C
A
N
B
U
S
Electrical Isolation
DC/DC
Converter
CAN Controller
SJA1000
Electrical Isolation
CAN Controller
SJA1000
Physical
CAN
Layer
2
nd
CAN Interface
only at
CAN-PCI104/200-2
Physical
CAN
Layer
DC/DC
Converter
10-pole
Male
Connector
10-pole
Male
Connector
PCI104
PCI Connector
Option:
PC104 ISA Connector
(only connected through)
Slot
Configuration