![ESD C.2046.02 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/esd/c-2046-02/c-2046-02_hardware-manual_2426428013.webp)
Technical Data
3.3 PC/104-Plus Bus (only with optional ISA Connector)
INFORMATION
The optional connectors are not equipped in the standard versions. They can be equipped
by esd on request. Please state this option in your order.
Specification
PC/104-Plus Specification Version 2.0
Host bus
PCI:
(according to PCI Spec. 2.2)
data range:
32 bit
clock rate:
33 MHz
signalling voltage:
3.3 V or 5 V
PCI bridge
PLX 9030
Assignment of the signals
INTx, REQ#, GNT#, CLK
configurable with the coding switch
(according to PCI-104 Spec. V.1.0)
ISA bus
ISA-bus signals are only connected through - no local connection
PCI connector
PC/104-Plus board connector, 120-pin
ISA connector
PC/104-Plus board connector, 40-pin and 64-pin
Table 4:
PC
/104-Plus
bus data (optional)
3.4 CAN Interface
Number of CAN
interfaces
1 (CAN-PCI-104/200-1),
2 (CAN-PCI104/200-2, CAN-PCI104/200-2T)
CAN controller
SJA1000, ISO 11898-1 (CAN 2.0)
Physical Layer
Physical layer Physical layer according to ISO 11898-2,
transmission rate programmable up to 1 Mbit/s
Electrical isolation
of the CAN
interface against
the other units
via dual channel digital isolator and DC/DC-converter
Bus termination
terminating resistor has to be set externally, if required
Table 5:
Data of the CAN interface
CAN-PCI104/200
Hardware Manual • Doc. No.: C.2046.21 / Rev. 1.1
Page 13 of 29