Страница 1: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 1 Colori compositi C M Y CM MY CY CMY K Quick reference guide ...

Страница 2: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 2 Colori compositi C M Y CM MY CY CMY K ...

Страница 3: ...Carefully read the operator s manuals provided with the system before operating the system In this manual control panel keys and software keys are graphically differentiated Control Panel Key Indicated directly by BLUE CAPITAL LETTERS or by the key icon Software Key Indicated by BLACK CAPITAL LETTERS The enter and context menu keys are respectively indicated as ENTER and UNDO keys in this manual T...

Страница 4: ...unctions PERFORMING AN EXAM 7 Working in B Mode 8 Working in M Mode 9 Working in CFM and Power Doppler 10 Working in Doppler 11 Multi View and Zoom 12 Frozen Images 13 Saving Images and Clips during the Exam 14 Reviewing Saved Exam Images and Clips MEASUREMENTS BODY MARKS AND ANNOTATIONS 15 Measurements 16 Body Marks 17 Entering Annotations 18 Printing Images ENDING AND ARCHIVING AN EXAM 19 Ending...

Страница 5: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 5 Colori compositi C M Y CM MY CY CMY K Starting an Exam Starting an Exam ...

Страница 6: ...es not light up check the power cable and the main switch placed on the rear of the system 2 Press the Main button and then the ON OFF button The Exam Start page appears after a certain time Procedure Main button System ON OFF Switch 1 Check that the power cable is connected Switch the system on by pressing the main button placed on the rear panel and then the ON OFF button 2 The Exam Start page a...

Страница 7: ...Turning the System OFF 1 Press the ON OFF button to shut down the system Procedure Note At power up the system prompts the operator to archive the last exam performed if the system was switched off without first closing the exam in progress This is a PC based system data loss or driver damage may occur if the system is turned off while working It is MANDATORY that the operator interrupts any pendi...

Страница 8: ...s worn out CAUTION The battery status led colour indicates both the status of the battery and the main power connection MyLab is either connected to the main power with its main switch on ON or the battery isn t under charge MyLab is connected to the main power and the battery pack is under charge Either MyLab is not connected to the main power or the main switch is on OFF Status Led Colour Meanin...

Страница 9: ...pending on its charging status The residual charge indicated in percentage is displayed below the battery icon and continuously updated Once the minimum threshold of the working condition is reached the residual operating time indicated in minutes is displayed besides the icon surrounded by a flashing yellow frame Carefully read the Getting Started manual for battery error messages Fully charged b...

Страница 10: ...ompositi C M Y CM MY CY CMY K 1 Patient Data 2 Application 3 Preset 4 Probe 5 Application Data At power up at the end of the initial auto test and at the start of every new exam START END key the system shows the following screen 1 5 2 3 4 3 Starting an Exam ...

Страница 11: ...st Patient Data field and press ENTER 2 Enter the patient s data using the keyboard 3 The Back Space key is used to remove input characters 4 To rapidly move through the different items use the Tab key 5 Place the cursor on the desired application and press ENTER to confirm 6 Place the cursor on the desired preset and press ENTER to confirm 7 Place the cursor on the desired probe and press ENTER t...

Страница 12: ...t the Edit ID option 3 Modify the desired data 4 Place the cursor on OK and press ENTER to confirm the changed data are displayed on the screen Do not use Edit ID option to begin a new exam as this will update the existing patient s information with new entries To activate a new procedure always use the START END key WARNING PROBE PRESET MENU Changing Patient Data ...

Страница 13: ...modify and save presets in real time in any application Before beginning the exam check that the active probe displayed on the screen matches the one selected on the Exam Start page WARNING Starting an Exam The PROBE PRESET key allows the user to save all the adjustments done in real time on the preset in any application 3 If necessary move the cursor on the required Probe and press ENTER to selec...

Страница 14: ...red peripheral units it also shows the following information center and patient data and the date Image Area the display of the image depends on various factors such as active mode selected application and transducer Software Keys Active application Active preset Active probe Color ROI and line cursors Icons of active cursors Software key for menus scrolling Software keys buttons Software keys for...

Страница 15: ...matically activates the trackball cursor When several cursors are present on the screen the ACTION key scrolls through the cursor and activates the active cursor ACTION key Active icons are displayed in green icons to be activated are displayed in yellow Mode Trackball Icon B Mode M Mode Doppler CFM Transmission focal point LINE cursor CFM ROI cursor 6 Trackball Functions Trackball Icons ...

Страница 16: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 16 Colori compositi C M Y CM MY CY CMY K Your Notes ...

Страница 17: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 17 Colori compositi C M Y CM MY CY CMY K Performing an Exam Performing an Exam ...

Страница 18: ...B Mode format can be redisplayed from any other mode using the B MODE key 2D Format Optimization 1 Adjust the gain B M gain key Rotate clockwise to increase the gain Rotate counterclockwise to decrease the gain 2 Adjust the depth DEPTH key Rotate clockwise to increase depth it reduces the image Rotate counterclockwise to reduce depth it enlarges the image Procedure POWER DEPTH B MODE B M gain FREQ...

Страница 19: ...rientation high low Press SIZE to change the scanning angle 4 Adjust the frequency FREQ key 5 Press the TEI key to activate the TEI mode which improves the brightness of the image by decreasing acoustic noise Press FREQUENCY key to select the TEI frequency RES value to improve resolution PEN to improve penetration 6 Adjust the focus by changing its position with the trackball To change the number ...

Страница 20: ...ey to obtain enhanced contrast resolution with a better tissue differentiation and a clear visualization of organ borders and structure margins TPVIEW key to activate the trapezoidal view with Linear probe enlarging the probe field s of view DYN RANGE key to characterize tissue structures reacting to compression echoes higher values smooth the image SHARPNESS key to accentuate the edges and the sm...

Страница 21: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 21 Colori compositi C M Y CM MY CY CMY K Your Notes Performing an Exam ...

Страница 22: ...M MY CY CMY K Procedure 1 Press LINE UPDATE to display the M Mode cursor 2 Position the cursor with the trackball on the relative B Mode line 3 Press M MODE to activate M Mode analysis Activating M Mode 8 Working in M Mode POWER DEPTH M MODE B M gain FREQ LINE UPDATE ACTION ...

Страница 23: ... value to improve resolution PEN to improve penetration 3 Adjust speed SWEEP key 4 Adjust the gain B M gain key Rotate clockwise to increase the gain Rotate counterclockwise to decrease the gain 5 Adjust the 2D real time display B FORMAT key 6 If necessary press B REF to view the M Mode trace at full screen 7 Rotate POWER to change the transmitted power using the minimum power compatible with a di...

Страница 24: ...d the small differences in tissues PLEX key to activate and update the 2D reference maintaining the trace in real time CMM key to activate Compass M Mode Compass M Mode The following image parameters can be individually adjusted using the following software keys Note During the exam LINE UPDATE freezes the trace and leaves the 2D reference in real time making the B Mode format software commands av...

Страница 25: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 25 Colori compositi C M Y CM MY CY CMY K Your Notes Performing an Exam ...

Страница 26: ... CFM and Power Doppler Procedure 1 Press CFM to activate Color Flow Mapping mode Press PWR D to activate the Power Doppler mode or press TVM to activate the Tissue Velocity mapping when available 2 Position the CFM ROI using the trackball Activating the Color Mode POWER CFM FREQ STEER CFM gain ACTION ...

Страница 27: ...cessary adjust the Color steering D STEER or STEER key Color Format Optimization When the steering is set to the maximum step color dots could be displayed because of artifacts Should this happen reduce the steering of one step WARNING 3 Activate the CFM ROI cursor by pressing the ACTION key to change the ROI size The ROI can then be resized using the trackball Move upward to reduce the ROI vertic...

Страница 28: ...lly adjusted using the following software keys CONCURR key to overlap the 2D and CFM sectors 2D CFM key to activate multiple views with 2D real time image on the left side of the screen and 2D CFM real time image on the right SMOOTH key to make the flow representation homogeneous SENSIT key to optimize the color sensitivity DENSITY key to change the line density PERSIST key to change the persisten...

Страница 29: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 29 Colori compositi C M Y CM MY CY CMY K Your Notes Performing an Exam ...

Страница 30: ...ss LINE UPDATE to display the Doppler cursor 2 Position the line CW or the Sample Volume PW with the trackball on the applicable area 3 Press PW to activate PW Doppler or CW to activate CW Doppler Activating Doppler Modes 10 Working in Doppler POWER CW FREQ STEER Doppler gain PW LINE UPDATE AUDIO ACTION ...

Страница 31: ...SEL key 5 Adjust the frequency FREQ key 6 If necessary adjust the Doppler steer D STEER or STEER key first activating the 2D real time PLEX key 7 If necessary press the ANGLE key to align the angle vector with the flow direction 8 If necessary change the size of the sample volume SV SIZE key 9 If necessary press the REVERSE key to reverse the flow direction 10 Adjust the 2D real time display B FOR...

Страница 32: ... general gain the baseline and the velocity range FILTER key to display low flow velocities lower filters fill the spectrum AUDIO key to adjust the Doppler volume HPRF key to double the sample volume only in Cardiac applications SMART D key to reverse the Doppler steering with reference to the vertical line SWEEP key to change the speed DYN RANGE key to adjust the compression of the reflected echo...

Страница 33: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 33 Colori compositi C M Y CM MY CY CMY K Your Notes Performing an Exam ...

Страница 34: ...e the image on the right left The real time image is displayed on the other side 3 Use or to switch between the right and left images Procedure Multi View To quit the multi view presentation press the B MODE key Dual Format Multi View format are available for two dual or four quad 2D and 2D CFM images Zoom is available both in real time and in Freeze 11 Multi View and Zoom ZOOM MULTI VIEW KEYS DEP...

Страница 35: ...ng are temporarily saved 12 Frozen Images Procedure 1 Press ZOOM to activate the ROI 2 Press the DEPTH key to change the zoom factor 3 Press ZOOM to activate the zoom 4 Move the image by using the trackball Zoom To quit the zoom function press ZOOM again The image returns to its original size The following image parameters can be individually adjusted using the software keys DUAL key to display tw...

Страница 36: ...ved both in real time and in Freeze Procedure Saving Images 1 The CLIP IMAGE key saves clips 2D or CFM in real time and in freeze when they are displayed in cine mode The key saves still images when either a single frame 2D or CFM or a trace Doppler or M Mode is displayed on the screen Note The CLIP DUR key changes the clip duration in real time CLIP IMAGE ...

Страница 37: ...s rotate the PAGE key to scroll to the next eight thumbnails 4 Press the PLAY key to display the sequence in cine mode The BEGIN END key automatically positions the scroll bar at the start or end of the sequence 5 Press the CINE MODE key to display the whole memory content or seconds intervals 6 Press the SPEED key to view the sequence at different speeds 14 Reviewing Saved Exam Images and Clips P...

Страница 38: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 38 Colori compositi C M Y CM MY CY CMY K Your Notes ...

Страница 39: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 39 Colori compositi C M Y CM MY CY CMY K Measurements Annotations and Printing Measurements Annotations and Printing ...

Страница 40: ...ments Measured values Operating instructions Select systolic 2AC view LLV dLV Vs 15 Measurements 1 Press the key to activate the Generic Measurements menu 2 Press the MEASURE key to display the Application Measurements menu REPORT MEASURE GENERIC MEASUREMENTS ADD TO RP key to add the generic measure to the exam report After this key is pressed the system asks to rename the measure The renamed meas...

Страница 41: ... to specific anatomic structures To display the measurements included in a group activate the group and press EXPAND Measurements Annotations and Printing 1 Press FREEZE to freeze the image 2 Press to display the measurements menu 3 Select the desired measurement using the trackball or by pressing the MEASURE key and press ENTER to confirm 4 Follow the instructions to perform the measurement the v...

Страница 42: ...LL key deletes all measurement cursors and the values displayed in the measurements field from the screen The UNDO key can be used to interrupt a single measurement before it has been confirmed the ACTION key interrupts the measurement sequence and exits from the measurement session The measurements already performed are marked with the symbol 3 Select the single parameter or the group to be measu...

Страница 43: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 43 Colori compositi C M Y CM MY CY CMY K Measurements Annotations and Printing Your Notes ...

Страница 44: ...ilable with the application is displayed on the right while the default mark is shown at the bottom left of the screen 3 Press the MARK key to scroll the body marks list displayed on the right side the active mark keeps being displayed while the list is scrolled 4 The trackball moves the arrow on the mark the ARROW key rotates it 5 Press the ENTER to confirm the arrow position Once the icon has be...

Страница 45: ...t the selection icon using the MARK key and pressing the ENTER key At the right of the image the system displays the list of available groups with the MARK key scroll the list and press ENTER to confirm the selection Select the Exit icon or press the UNDO key to exit without displaying any body mark Selection Icon Exit Icon Measurements Annotations and Printing ...

Страница 46: ...3 Press ENTER to confirm the position Procedure Annotation Mode The procedure can be repeated several times Entering Annotations 1 Press the ANNOT key the system displays the list of available words on the right of the screen 2 Select the By Word glossary The key WRD SENT toggles from the By Word to the By Sentence glossary associated to the application By Word Glossary ANNOT 17 Entering Annotatio...

Страница 47: ... of available words on the right of the screen 2 Select the By Sent glossary 3 Scroll the lists through softkeys and select the desired words highlighted in yellow The sentence is automatically updated as the lists are scrolled The sentence can be edited by pressing the ACTION key 4 Place the sentence using the trackball 5 Press ENTER to confirm By Sentence Glossary The sentence is composed of fou...

Страница 48: ...cursor is displayed 2 Move the cursor near the text to be corrected Press ENTER to activate the text the text color turns to yellow 3 Press the CLEAR key the selected text is deleted Deleting Text The CLEAR ALL key deletes the text and exits from the annotation session The DEL LAST key deletes the last inserted word or sentence Procedure 1 Press the ARROW key an arrow is displayed on the screen 2 ...

Страница 49: ...o print on the printer shown on the left icon 2 on the printer shown on the right The icons of the set peripherals are displayed at the right bottom of the screen B W Printer RGB Printer PC Printer DICOM Printer No Peripheral Printer Icon PERIPHERALS KEYS Measurements Annotations and Printing 18 Printing Images ...

Страница 50: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 50 Colori compositi C M Y CM MY CY CMY K Your Notes ...

Страница 51: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 51 Colori compositi C M Y CM MY CY CMY K Measurements Annotations and Printing Your Notes ...

Страница 52: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 52 Colori compositi C M Y CM MY CY CMY K Your Notes ...

Страница 53: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 53 Colori compositi C M Y CM MY CY CMY K Ending and Archiving an Exam Ending and Archiving an Exam ...

Страница 54: ...ng an exam the images clips are temporarily stored on the system s hard disk As soon as the START END key is pressed the system shows the end exam window This window shows the patient s name the type of activated application and the size of the exam data The operator is enabled to simultaneously save the exam to different supports in different formats 19 Ending the Exam ...

Страница 55: ... RW DVD R R single layer USB Memory Drive Network directory CD R and RW DVD R R single layer USB Memory Drive Network directory Dicom Storage Server Procedure 1 Press the START END key to end the exam 2 Set whether patient data have to be made anonymous Anonymize field 3 Select how to save data and the destination support 4 Place the cursor on OK and press ENTER Data are saved If no option is sele...

Страница 56: ... Pagina 56 Colori compositi C M Y CM MY CY CMY K Images and Clips can be reloaded for each patient and a specific exam can be reviewed Specific measurements can be taken and saved on the reloaded images 20 Reviewing the Archive ARCHIVE REV ...

Страница 57: ...all or by pressing the SCROLL key The thumbnails of the highlighted exam are shown at the bottom of the screen 2 Press ENTER twice to display the highlighted exam images at full screen or place the cursor on the archive display icon and press ENTER Archive Display Icon Archive Icon Exam List Archive images clips of selected exam Ending and Archiving an Exam ...

Страница 58: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 58 Colori compositi C M Y CM MY CY CMY K Your Notes ...

Страница 59: ...QG_ML25 30GOLD RevC 3 19 03 2009 10 10 Pagina 59 Colori compositi C M Y CM MY CY CMY K Ending and Archiving an Exam Your Notes ...

Страница 60: ...0 10 Pagina 60 Colori compositi C M Y CM MY CY CMY K ESAOTE s p a International Activities Via di Caciolle 15 50127 Firenze ITALY Phone 39 055 4229 1 Fax 39 055 4229 208 international sales esaote com www esaote com 8300499000 MA Rev C ...

Отзывы: