-- 51 --
fzb2d3ea
12.10 START SEQUENCE MENU
Cable area (mm2)
X
Weldhead offset, mm
START SEQUENCE MENU
STOP SEQUENCE MENU
CALIBRATION MENU
DISPLAY MENU
ERROR LIST
Test
0 / 1 / 2
The following menu is shown when
START SEQUENCE MENU
has been selected:
START PHASE 1
START PHASE 2
Max OCV
Off / On
On some occasions, for example when welding with special electrodes or materials,
it can be necessary to make up a special start sequence. The start method can also
influence the appearance of the weld bead.
The start sequence is divided into two phases (
PHASE1
and
PHASE2
). The time
and percentage values of the two phases can be adjusted.
N.B.
PHASE2 is not available in the Chinese version.
PHASE2
has no effect if
t = 0
in
PHASE1
.
t = the durability of the sequence, indicated in intervals of 0.1 s (max. 99.9 s).
Max OCV
(Max open circuit voltage)
On -- 50 V at start, after weld arc it returns to set value.
Off -- Set value at start.
GB
Содержание PEH 4.3
Страница 10: ...10 fzb2d1ea GB...
Страница 14: ...14 fzb2d2ea 4 CONNECTION DIAGRAM GB...
Страница 15: ...15 fzb2d2ea GB...
Страница 16: ...16 fzb2d2ea 5 COMPONENT POSITIONS ON CIRCUIT BOARD AP2 GB...
Страница 17: ...17 fzb2d2ea 6 COMPONENT POSITIONS ON CIRCUIT BOARD AP1 GB...