SECTION 6
REPLACEMENT PARTS
29
Replacement parts may be ordered from your ESAB
distributor or from:
ESAB Welding & Cutting Products
Attn: Customer Service Dept.
PO Box 100545, Ebenezer Road
Florence, SC, 29501-0545
Be sure to indicate any special shipping instructions
when ordering replacement parts.
To order parts by phone, contact ESAB at 1-803-664-
5540 or 4460. Orders may also be faxed to 1-800-634-
7548. Be sure to indicate any special shipping instruc-
tions when ordering replacement parts.
Refer to the Communication Guide located on the last
page of this manual for a list of customer service phone
numbers.
6.1 GENERAL
Replacement Parts are illustrated on the following fig-
ures. When ordering replacement parts, order by part
number and part name, as illustrated on the figure. DO
NOT ORDER BY PART NUMBER ALONE.
Always provide the series or serial number of the unit on
which the parts will be used. The serial number is
stamped on the unit nameplate.
6.2 ORDERING
To assure proper operation, it is recommended that only
genuine ESAB parts and products be used with this
equipment. The use of non-ESAB parts may void your
warranty.
MANUAL CHANGES:
The A edition of this Instruction Manual covers the following changes or upcoming changes:
1. PCB5 PC board assembly P/N 38037 was changed to 38039 on the 460V and 400V units starting with Serial No. PD-I532171
in August, 1995. This change eliminated the red and blue wires from PCB5 to J1 receptacle. This change will also be
implemented on the 230V models soon.
2. 15A, 250V Fuse (F1) P/N 951780 will be replaced by a 12A, 600V fuse P/N 952159. This requires a different fuse holder (P/
N 951797 to 952136) which is not interchangeable. Therefore, if replacing fuse, be sure to use the same rated fuse.
3. PC board assembly P/N 38014 (PCB2 and PCB3) now includes two 1/2 amps fuses P/N 952014.
4. R2 and R15 resistor 5K ohm, 20W, N.I. P/N 17313500 was changed to 10K ohm, 20W, N.I., P/N 17290210 resistor plus two
more 10K resistors (R13 and R14) were added to the 460V power sources.
5. Regulator Housing P/N 33955GY was changed to 35903GY.
Содержание PCM-750i
Страница 25: ...25 Figure 5 1 PCM 750i Series A Schematic Diagram 460 V 3 Phase Input D 35511 A ...
Страница 26: ...26 Figure 5 2 PCM 750i Series A Wiring Diagram 460 V 3 Phase Input D 35510 A ...
Страница 27: ...27 Figure 5 3 PCM 750i Series A Schematic Diagram 230 V 1 Phase Input D 35507 A ...
Страница 28: ...28 Figure 5 4 PCM 750i Series A Wiring Diagram 230 V 1 Phase Input D 35506 A ...