SECTION 5
TROUBLESHOOTING
22
E.
Red "FAULT" light ON.
Is the unit overheated?
("Fault" lights turns off
when Unit cools down.)
Yes
No
Is air flowing?
Duty cycle exceeded:
40% @ 50 A, 60% @ 80 A,
Yes
No
or 100% @ 50 A output
See page 5-2
Is input voltage below 150 or above 270 volts?
(Not recommended to operate above 253 V or below 190 V.)
Yes
No
Adjust voltage
•
Repair power source
Fault light will energize if voltage falls below 175 volts for 0.3 seconds or exceeds 260 volts even for an instant.
The light will not turn OFF even when correct voltage is restored. Reset by placing PCM-750i power switch
OFF and then ON again.
NOTE: When in LOCK-IN mode, the FAULT light will turn on during second "trigger". This does not affect
performance. Turn off.
•