![ESAB OrigoMag C140 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/esab/origomag-c140/origomag-c140_instruction-manual_2425127008.webp)
−
8
−
OC140e
5.4
Mains power supply
Check that the unit is connected to the correct mains power supply voltage, and that it is protected by
the correct fuse size. A protective earth connection must be made, in accordance with regulations.
Rating plate with supply connection data
OrigoMag C140
Voltage V
230V, 1
∼
50/60Hz
Current A
at 100% duty cycle
5,4
at 60% duty cycle
7,6
at 20% duty cycle
13,8
Cable area mm
2
3 x 1.5
Fuse
slow
A
10
NB: The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
6
OPERATION
General safety regulations for the handling of the equipment can be found on
page 3. Read through before you start using the equipment!
WARNING!
Rotating parts can cause injury, take great care.
WARNING
−
TIPPING RISK!
There is a risk of tipping while transportation and operation, if the welding machine leans
more than 10
o
. In that case appropriate securing has to be provided !