1

DIRECTIVE

DECLARATION OF CONFORMITY

ESAB Welding Equipment AB, S

695 81 Laxå, Sweden, gives its unreserved guarantee that welding

power source OrigoMag C140 from serial number 507 complies with standard IEC/EN 60974

1, in

accordance with the requirements of directive (73/23/EEC) and addendum (93/68/EEC) and with

standard EN 60974

10 in accordance with the requirements of directive (89/336/EEC) and addendum

(93/68/EEC).

−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−

Henry Selenius

Vice President

ESAB Welding Equipment AB

695 81 LAXÅ

SWEDEN

Tel: + 46 584 81000

 Fax: + 46 584 411924

Laxå 2005

08

31

2

SAFETY

Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who

works on or near the equipment observes all the relevant safety precautions. Safety precautions

must meet the requirements that apply to this type of welding equipment. The following recommen-

dations should be observed in addition to the standard regulations that apply to the workplace.

All work must be carried out by trained personnel well

acquainted with the operation of the welding

equipment. Incorrect operation of the equipment may lead to hazardous situations which can result

in injury to the operator and damage to the equipment.
1.

Anyone who uses the welding equipment must be familiar with:

S

its operation

S

location of emergency stops

S

its function

S

relevant safety precautions

S

welding

2.

The operator must ensure that:

S

no unauthorised person is stationed within the working area of the equipment when it is

started up.

S

no

one is unprotected when the arc is struck

3.

The workplace must:

S

be suitable for the purpose

S

be free from draughts

4.

Personal safety equipment

S

Always wear recommended personal safety equipment, such as safety glasses, flame

proof

clothing, safety gloves.

S

Do not wear loose

fitting items, such as scarves, bracelets, rings, etc., which could become

trapped or cause burns.

5.

General precautions

S

Make sure the return cable is connected securely.

S

Work on high voltage equipment 

may only be carried out by a qualified electrician.

S

Appropriate fire extinquishing equipment must be clearly marked and close at hand.

S

Lubrication and maintenance must 

not 

be carried out on the equipment during operation.

GB

Содержание OrigoMag C140

Страница 1: ...Valid for serial no 507 0349 301 105 050913 OrigoMag C140 Instruction manual ...

Страница 2: ...1 Placing 6 5 2 Assembly of components 6 5 3 Electrical installation 7 5 4 Mains power supply 8 6 OPERATION 8 6 1 Connection and control devices 9 6 2 Functions explanation 9 7 MAINTENANCE 9 7 1 Inspection and cleaning 9 8 FAULT TRACING 10 9 ORDERING OF SPARE PARTS 10 DIAGRAM 11 WEAR COMPONENTS 13 ACCESSORIES 14 ...

Страница 3: ...cquainted with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1 Anyone who uses the welding equipment must be familiar with S its operation S location of emergency stops S its function S relevant safety precautions S welding 2 The operator must ensure that S no unaut...

Страница 4: ...ntilation extraction at the arc or both to take fumes and gases away from your breathing zone and the general area ARC RAYS Can injure eyes and burn skin S Protect your eyes and body Use the correct welding screen and filter lens and wear protective clothing S Protect bystanders with suitable screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore that there are no infl...

Страница 5: ...rmissible load at 100 duty cycle 42A 60 duty cycle 54A 20 duty cycle 100A Setting range DC 35A 130A Open circuit voltage 20 28V Open circuit power 90W Power factor at max load 0 92 Control voltage 230V 50 60Hz Wire feed speed 2 0 14m min Welding gun connection fixed Wire dimension range 0 6 0 8 Fe 0 8 cored 0 8 CuSi Max diameter weight of wire bobin 200mm 5kg Dimensions lxwxh 650x300x550 Weight 25...

Страница 6: ...is designed for use in areas with increased electrical hazard 5 INSTALLATION The installation must be executed by a professional 5 1 Placing Position the welding power source such way that its cooling air inlets and outlets are not obstructed 5 2 Assembly of components GB ...

Страница 7: ... 7 OC140e 5 3 Electrical installation GB ...

Страница 8: ... 10 NB The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations They may not be applicable in other countries make sure that the cable area and fuse sizes comply with the relevant national regulations 6 OPERATION General safety regulations for the handling of the equipment can be found on page 3 Read through before you start using the equipment WARNING Rotatin...

Страница 9: ...he front of the ma chine It resets automatically when the temperature has fallen 7 MAINTENANCE Regular maintenance is important for safe reliable operation Note All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work in the product during the guarantee period in order to rectify any faults 7 1 Inspection and cleaning Check regularly that the power sour...

Страница 10: ...equently S Check to see whether the air inlets outlets are clogged S Make sure that you are not exceeding the rated data for the power source i e that the unit is not being overloaded Poor welding performance S Check that the welding current supply and return cables are correctly connected S Check that the correct current value is set S Check that the correct welding wires are being used S Check t...

Страница 11: ...Diagram 11 dOC140 OrigoMag C140 230V ...

Страница 12: ...OrigoMag C140 Edition 050913 12 oOC140 Valid for serial no 507 XXX XXXX Ordering numbers 0349 306 220 OrigoMag C140 230V 1 50 60Hz ...

Страница 13: ...13 13 wOC140 Wear components W F Mechanism 0469 475 880 Item Denomination Ordering no Notes A Feed roller kit 0469 517 880 Ø 0 6 0 8mm Fe cored wire The rollers are marked with wire dimension in mm some are also marked with inch ...

Страница 14: ...OrigoMag C140 Edition 050913 Accessories 14 aOC140 Traction KIT 0349 309 073 ...

Страница 15: ...al AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel 54 11 4 753 4039 Fax 54 11 4 753 6313 BRAZIL ESAB S A Contagem MG Tel 55 31 2191 4333 Fax 55 31 2191 4440 CANADA ESAB Group Canada Inc Missisauga Ontario Tel 1 905 670 02 20 Fax 1 905 670 48 79 MEXICO ESAB Mexico S A Mo...

Отзывы: