3 TECHNICAL DATA
0463 279 001
- 8 -
© ESAB AB 2015
3
TECHNICAL DATA
Mig 4004i
Mig 5004i
Mains voltage
380-440 V, +/- 10%,
3~ 50/60 Hz
380-440 V, +/- 10%,
3~ 50/60 Hz
Mains supply S
scmin
1.8 MVA
2.2 MVA
Mains supply Z
max
-
0.22 Ω
Primary current I
max
26 A
36 A
No-load power
in energy-saving
mode 6.5 min. after welding
40 W
40 W
Setting range
MIG/MAG
16 A/15 V - 400 A/34 V
16 A/15 V - 500 A/39 V
MMA
16 A/20 V - 400 A/36 V
16 A/21 V - 500 A/40 V
Permissible load at MIG/MAG
60 % duty cycle
400 A/34 V
500 A/40 V
80 % duty cycle
-
400 A/34 V
100% duty cycle
350 A/31.5 V
350 A/31.5 V
Permissible load at MMA
60 % duty cycle
400 A/36 V
500 A/40 V
80 % duty cycle
-
400 A/36 V
100% duty cycle
350 A/34 V
350 A/34 V
Power factor
at maximum current 0.93
0.95
Efficiency
at maximum current
89 %
89 %
Open-circuit voltage
VRD function inactivate
1)
55 V
55 V
VRD function active
1)
<35 V
<35 V
Operating temperature
-10 to +40°C
-10 to +40°C
Transportation temperature
-20 to +55°C
-20 to +55°C
Constant sound pressure when
idling
<70 db (A)
<70 db (A)
Dimensions l × w × h
610 × 250 × 445 mm
610 × 250 × 445 mm
Weight
46 kg
46 kg
Insulation class
H
H
Enclosure class
IP 23
IP 23
Application class
1)
The VRD function is explained in chapter "VRD (Voltage Reducing Device)"
Mains supply, S
sc min
Minimum short circuit power on the network in accordance with IEC 61000-3-12.
Mains supply, Z
max
Maximum permissible line impedance of the network in accordance with IEC 61000-3-11.