4 INSTALLATION
0463 279 001
- 12 -
© ESAB AB 2015
NOTE!
The power source can be connected for generator power. For more information,
contact authorised ESAB service personnel.
Check that the unit is connected to the correct mains power supply voltage, and that it is
protected by the correct fuse size. A protective earth connection must be made, in
accordance with regulations.
A.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable areas
Mig 4004i
Mig 5004i
Mains voltage
380-440V, +/- 10%, 3~50/60 Hz
Mains cable area
4G4 mm
2
4G6 mm
2
Phase current I
eff
Uin 380 V
21 A
27 A
Fuse
anti-surge
25 A
35 A
Fuse
Type C MCB-surge
32 A
32 A
Phase current I
eff
Uin 400 V
19 A
26 A
Fuse
anti-surge
20 A
35 A
Fuse
Type C MCB-surge
32 A
32 A
Phase current I
eff
Uin 440 V
18.5 A
24 A
Fuse
anti-surge
20 A
25 A
Fuse
Type C MCB-surge
32 A
32 A
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with
Swedish regulations. They may not be applicable in other countries: make sure
that the cable area and fuse sizes comply with the relevant national regulations.