ESAB CUTMASTER 120
SERVICE
300X5398
5-4
5.05 Basic Troubleshooting Guide
WARNING
There are extremely dangerous voltage and power levels present inside this unit. Do
not attempt to diagnose or repair unless you have had training in power electronics
measurement and troubleshooting techniques.
Problem - Symptom Possible Cause
Recommended Action
ON / OFF Switch
is ON but the A/C
Indicator does not
light
1. Primary power disconnect is in OFF
position.
2. Primary fuses / breakers are blown
or tripped.
3. Units internal fuse blown.
4. Faulty components in unit.
1. Turn primary power disconnect switch to ON position.
2. a) Have qualified person check primary fuses / breakers.
b) Connect unit to known good primary power receptacle
3. a) Replace fuse.
b) If fuse blows again, return to authorized service center for
repair or replacement.
4. Return to authorized service center for repair or replacement.
Fault indicator
flashing, 65 PSI
indicator flashing
1. Improper Input Voltage.
2. Primary input voltage problem.
3. Faulty components in unit.
1. Check for proper primary input voltage.
2. Have qualified person check primary voltage to insure it meets
unit requirements see section 2.05.
3. Return to authorized service center for repair or replacement.
TEMPERATURE
indicator ON. FAULT
indicator flashing.
1. Air flow through or around the unit
is obstructed.
2. Duty cycle of the unit has been
exceeded
3. Failed components in unit
1. Refer to clearance information – section 2.04
2. Allow unit to cool.
3. Return to authorized service center for repair or replacement.
GAS LED OFF,
FAULT and MIN
pressure indicators
flashing.
1. Gas supply not connected to unit.
2. Gas supply not turned ON.
3. Gas supply pressure too low.
4. AIR PRESSURE CONTROL
regulator set too low.
5. Failed components in unit.
1. Connect gas supply to unit.
2. Turn gas supply ON.
3. Set air supply inlet pressure to unit to 120 psi.
4. Adjust regulator to set air pressure - see section 4.02.
5. Return to authorized service center for repair or replacement.
FAULT and 70 PSI
indicators flashing.
1. Shield Cup loose.
2. Torch not properly connected to
power supply.
3. Problem in torch and leads PIP
circuit.
4. Failed components in unit.
1. Hand tighten the shield cup until it is snug.
2. Insure torch ATC is securely fastened to unit.
3. Replace torch and leads or return to authorized service center
for repair or replacement.
4. Return to authorized service center for repair or replacement.
FAULT and 75 PSI
indicators flashing.
1. Start signal is active when ON/OFF
SWITCH is turned to ON position.
2. Problem in the torch and leads
switch circuit.
3. Failed components in unit.
1. Start can be active for one of the following:
• Hand torch switch held closed
• Hand pendant switch held closed
• CNC START signal is active low
Release the START signal source
2. Replace torch and leads or return to authorized service center
for repair or replacement.
3. Return to authorized service center for repair or replacement.
Содержание Cutmaster 100 SL100 1Torch
Страница 9: ...This Page Intentionally Blank...
Страница 12: ...ESAB CUTMASTER 120 300X5398BG 1 1 1 0 ESAB 1 2 3 4 5 2002 96 E ESAB ESAB 1...
Страница 13: ...ESAB CUTMASTER 120 300X5398BG 1 2 m...
Страница 48: ...ESAB CUTMASTER 120 300X5398RU 1 1 1 0 ESAB 1 B 2 3 4 5 2002 96 EC ESAB ESAB 1...
Страница 49: ...ESAB CUTMASTER 120 300X5398RU 1 2 Class Class...
Страница 56: ...ESAB CUTMASTER 120 300X5398 GENERAL INFORMATION This page intentionally blank...
Страница 64: ...ESAB CUTMASTER 120 INTRODUCTION 300X5398 2T 4 This Page Intentionally Blank...
Страница 70: ...ESAB CUTMASTER 120 INSTALLATION 300X5398 3T 2 This Page Intentionally Blank...
Страница 74: ...ESAB CUTMASTER 120 OPERATION 300X5398 4 4 This Page Intentionally Blank...
Страница 93: ...ESAB CUTMASTER 120 300X5398 OPERATION 4T 19 This Page Intentionally Blank...
Страница 96: ...ESAB CUTMASTER 120 OPERATION 300X5398 4T 22 This Page Intentionally Blank...
Страница 111: ...ESAB CUTMASTER 120 300X5398 PARTS LIST 6 5 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13...
Страница 117: ...ESAB CUTMASTER 120 300X5398 APPENDIX A 5 This Page Intentionally Blank...
Страница 121: ...This Page Intentionally Blank...