TIG (GTAW) Welding 5-6 0-5555
Programming Parameter
Adjustment
Device
Display
Factory Setting
Up Slope
This parameter operates in (4T)
TIG modes only and is used to
set the time for the weld current
to ramp up, after the torch trigger
switch has been depressed then
released, from INITIAL CUR to
PEAK or BASE current.
Range: 0.0 to 15.0 seconds
1 second
Base Current
This parameter sets the current
at AC or DC TIG mode, and the
lowest current at DC or AC pulse
TIG mode. This parameter also
sets the STICK weld current.
Range:
10 to 205 Amps (DC and AC
TIG mode)
10 Amps to peak current (DC
and AC Pulse TIG mode)
80 Amps (DC TIG
mode)
100 Amps (AC TIG
mode)
50 Amps (DC Pulse
and AC Pulse TIG
modes)
Peak Current
This parameter sets the PEAK
weld current when in DC or AC
Pulse TIG mode.
Range: 10 to 205 Amps
100 Amps (DC Pulse
and AC Pulse TIG
modes)
Pulse Width
This parameter sets the
percentage on time of the PULSE
FREQUENCY for PEAK weld
current when in DC or AC Pulse
TIG mode.
Range: 10 to 90%
50% (DC Pulse and
AC Pulse TIG modes)
Pulse Frequency
This parameter sets the PULSE
FREQUENCY when in DC or AC
Pulse TIG mode.
Range: 0.2 to 200 Hz
1 Hz
Down Slope
This parameter operates in 4T
TIG modes only and is used to
set the time for the weld current
to ramp down, after the torch
trigger switch has been pressed,
to crater current. This control is
used to eliminate the crater that
can form at the completion of a
weld.
Range: 0.0 to 25.0 seconds
1 second
Содержание CIGWELD WeldSkill 205AC/DC
Страница 8: ...This Page Intentionally Blank...
Страница 14: ...GENERAL INFORMATION 1 6 0 5555 This Page Intentionally Blank...
Страница 28: ...INSTALLATION 3 6 0 5555 This page is left blank intentionally...
Страница 68: ...APPENDIX A 2 0 5555 This Page Intentionally Blank...
Страница 71: ...This Page Intentionally Blank...