-- 5 --
bh26d1e
4
TECHNICAL DATA
CaddyArc 150
Mains voltage
230 V, 1
µ
50/60 Hz
Fuse (delayed--action)
16 A
Primary current
I
max
36 A
Primary current
I
eff
21 A
Voltage/current range
(DC)
4 A /20 V -- 150 A /26 V
Maximum permissible load at
25% duty cycle
35% duty cycle
60% duty cycle
100% duty cycle
150 A / 26 V
140 A / 26 V
110 A / 25 V
90 A / 24 V
Power factor
at maximum current
0,62
Efficiency
at maximum current
77%
Open--circuit voltage
71--78 V
Operating temperature
--10
˚
C -- +40
˚
C
Constant A--weighed sound pressure
< 70 db
Dimensions, l x b x h
394 x 267 x 274 mm
Weight
9 kg
Enclosure class
IP 23C
Application class
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading.
Enclosure class
The
IP
code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked
IP23
is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
5
INSTALLATION
The installation must be executed by a professional.
WARNING!
This product is intended for industrial use. In a domestic environment this product may cause radio
interference. It is the user’s responsibility to take adequate precautions.
5.1
Placing
Place the power source so that its cooling air inlets and outlets are not obstructed.
5.2
Rating plate
The rating plate is located on the underside of the power source.
GB