background image

Edition 041101

CaddyArc 150

Accessories

-- 16 --

bh26a

MMA welding and return cable kit

. . . . . . .

(”crocodile” type holder)

0349 501 078

MMA welding and return cable kit

. . . . . . . .

(”screwe” type holder)

0349 501 079

Remote control MMA 1

(10 m cable) . . . . . . .

MMA and TIG: current

0349 501 024

Foot control FS002

. . . . . . . . . . . . . . . . . . . . . .

MMA and TIG current

0349 090 886

Remote control unit AT1

. . . . . . . . . . . . . . . . .

MMA and TIG: current

0459 491 896

Remote control unit AT1 CF

. . . . . . . . . . . . .

MMA and TIG: rough and fine setting of

current.

0459 491 897

Remote cable 12 pole -- 8 pole

5 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0459 552 880
0459 552 881
0459 552 882
0459 552 883

Shoulderstrap

. . . . . . . . . . . . . . . . . . . . . . . . . . 0459 367 880

Содержание CaddyArc 150

Страница 1: ...GB Valid for serial no 316 xxx xxxx 328 xxx xxxx 341 xxx xxxx 0459 263 001 GB 041101 CaddyArc 150 Instruction manual...

Страница 2: ...te 5 5 3 Mains power supply 6 6 OPERATION 6 6 1 Connections and control devices 6 6 2 Control panel 7 6 3 Settings 8 6 4 Overheating protection 8 6 5 MMA welding 8 6 6 TIG welding 9 6 7 Remote control...

Страница 3: ...e carried out by trained personnel well acquainted with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the o...

Страница 4: ...y Use the correct welding screen and filter lens and wear protective clothing S Protect bystanders with suitable screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore tha...

Страница 5: ...ercentage of a ten minute period that you can weld at a cer tain load without overloading Enclosure class The IP code indicates the enclosure class i e the degree of protection against penetration by...

Страница 6: ...duty cycle 120A 35 duty cycle 150A 35 duty cycle 10 A 16 A 20 A Mains cable area 3 x 2 5 mm2 Welding cable area 16 mm2 Note The installed plug is approved for max 16A North American version The mains...

Страница 7: ...e control unit 8 Indicating lamp green mains power supply 9 Indicating lamp yellow for overheating 6 2 2 Panel function symbols MMA Amp Volt Fj rrdon TIG Hot Start Arc Force 6 2 3 Hidden functions A n...

Страница 8: ...ately melts and sticks to the metal rendering continued welding impossible Therefore the arc has to be struck in the same way that you would light a match Quickly strike the electrode against the meta...

Страница 9: ...ich menu is displayed This value is displayed in the main menu only 6 6 TIG welding TIG welding melts the metal of the workpiece using an arc struck from a tungsten electrode which does not itself mel...

Страница 10: ...arc S Check that the mains power supply switch is turned on S Check that the welding current supply and return cables are correctly connected S Check that the correct current value is set S Check to...

Страница 11: ...utton If the fault persists contact a service workshop E10 20V fault 18 5 21 5 V Automatic reset once fault has disappeared E11 15 V fault 13 0 16 0 Automatic reset once fault has disappeared E13 High...

Страница 12: ...Diagram 12 CaddyArc150...

Страница 13: ...13 CaddyArc150...

Страница 14: ...4 bh26o Ordering no Denomination Type 0459 199 880 Welding Power source CaddyArc 150 for 230 V mains voltage 0459 199 886 Welding Power source CaddyArc 150 for 230 V mains voltage North American versi...

Страница 15: ...CaddyArc 150 Edition 041101 Spare parts list 15 bh26s Item Qty Ordering no Denomination 101 1 0459 277 001 Filter...

Страница 16: ...mote control MMA 1 10 m cable MMA and TIG current 0349 501 024 Foot control FS002 MMA and TIG current 0349 090 886 Remote control unit AT1 MMA and TIG current 0459 491 896 Remote control unit AT1 CF M...

Страница 17: ...17 p...

Страница 18: ...l AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel 54 11 4 753 4039 Fax...

Отзывы: