5 OPERATION
0440 001 001
- 14 -
© ESAB AB 2020
5.2.1
Manual mode
A
Voltage setting
B
Wire feed speed setting
C
Inductance setting
D
Manual/QSet mode
E
Wire feed speed
F
Welding current
G
Welding voltage
The operator must set appropriate values for the wire feed speed and welding voltage.
5.2.2
QSet mode
A
QSet value setting
B
Plate thickness setting
C
Material selection/
Inductance setting
D
Manual/QSet mode
E
Wire feed speed
F
Welding current
G
Welding voltage
H
QSet value
I
Plate thickness
In QSet mode the appropriate welding voltage is automatically set by the power source. QSet
monitors the welding arc and continuously adjusts the voltage to maintain the optimal setting.
Calibration
The first time you use QSet mode, and when you change welding wire, material or shielding
gas, you need to allow QSet to calibrate. This is done by making a test weld (min. 6
seconds). Simply start welding and let QSet find the correct parameter settings.