SAFETY

Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who works on or near the equipment
observes all the relevant safety precautions. Safety precautions must meet the requirements that apply to this type of welding
equipment. The following recommendations should be observed in addition to the standard regulations that apply to the work­
place.

All work must be carried out by trained personnel well-acquainted with the operation of the welding equipment. Incorrect oper­
ation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment.

1.

Anyone who uses the welding equipment must be familiar with:

its operation

location of emergency stops

its function

relevant safety precautions

welding

2.

The operator must ensure that:

no unauthorized person is stationed within the working area of the equipment when it is started up.

no-one is unprotected when the arc is struck

3.

The workplace must:

be suitable for the purpose

be free from drafts

4.

Personal safety equipment

Always wear recommended personal safety equipment, such as safety glasses, flame-proof clothing, safety gloves.

Do not wear loose-fitting items, such as scarves, bracelets, rings, etc., which could become trapped or cause burns.

5.

General precautions

Make sure the return cable is connected securely.

Work on high voltage equipment 

may only be carried out by a qualified electrician.

Appropriate fire extinquishing equipment must be clearly marked and close at hand.

CAUTION

Class A equipment is not intended for use in residential locations where
the electrical power is provided by the public low-voltage supply system.
There may be potential difficulties in ensuring electromagnetic
compatibility of class A equipment in those locations, due to conducted
as well as radiated disturbances.

GB

Содержание Caddy Arc 152i

Страница 1: ...Valid for serial no 803 xxx xxxx 0460 448 074 20120524 Caddy Arc 152i RU GB Instruction manual...

Страница 2: ...2 Rights reserved to alter specifications without notice English 3 12...

Страница 3: ...nimum cable area 7 5 OPERATION 8 5 1 Connections and control devices 8 5 2 Control panel A31 8 5 3 Connection of welding and return cable 8 5 4 Overheating protection 9 5 5 MMA welding 9 5 6 TIG weldi...

Страница 4: ...st ensure that no unauthorized person is stationed within the working area of the equipment when it is started up no one is unprotected when the arc is struck 3 The workplace must be suitable for the...

Страница 5: ...both to take fumes and gases away from your breathing zone and the general area ARC RAYS Can injure eyes and burn skin Protect your eyes and body Use the correct welding screen and filter lens and wea...

Страница 6: ...ture 20 C 55 C Constant sound pressure in open circuit 70 db A Dimensions l x b x h 418 x 188 x 208 mm Weight 7 8 kg Enclosure class IP 23 Application class Duty cycle The duty cycle refers to the tim...

Страница 7: ...mains cable area A protective earth connection must be made in accordance with regulations Location of rating plate 4 2 1 Recommended fuse sizes and minimum cable area Arc 152i Mains voltage 230 V 10...

Страница 8: ...voltage LED green Thermal overload trip indicator yellow 5 3 Connection of welding and return cable The power source has two outputs a positive terminal and a negative terminal for connecting welding...

Страница 9: ...oo long it will crackle and spit before finally going out com pletely If you are working on a welding bench check before attempting to strike the arc that residual waste metal pieces of electrode or o...

Страница 10: ...regular intervals in order to achieve trouble free welding 7 FAULT TRACING Try these recommended checks and inspections before sending for an authorised service technician Type of fault Corrective ac...

Страница 11: ...DISMANTLING AND SCRAPPING Welding equipment primarily consists of steel plastic and non ferrous metals and must be handled according to local environmental regulations Coolant must also be handled acc...

Страница 12: ...TOCr 12 1 13 2 15 2 1 15 3 15 4 16 4 1 16 4 2 16 4 2 1 16 5 17 5 1 17 5 2 A31 17 5 3 17 5 4 18 5 5 MA 18 5 6 TIG 18 6 19 6 1 19 7 20 8 20 9 20 22 24 25...

Страница 13: ...bh31d1r 13 1 ESAB 1 B 2 3 4 5 Class Class RU...

Страница 14: ...bh31d1r 14 o a c ap a pe a o ac a c o e pa a c opo T M ESAB RU...

Страница 15: ...rc 125li TIG 2 1 Arc 152i 3 25 3 Arc 152i 230 1 50 60 I1 35 A 30 8 150 A 25 35 60 100 150 A 26 0 140 A 25 6 110 A 24 4 90 A 23 6 0 63 78 58 75 10 C 40 C 20 C 55 C 70 A x x 418 x 188 x 208 7 8 IP 23 40...

Страница 16: ...bh31d1r 16 4 4 1 4 2 4 2 1 Arc 152i 230 10 1 2 3 2 5 2 I1 20 A 16 2 C 20 32 A 16 RU...

Страница 17: ...bh31d1r 17 5 13 5 1 1 MMA IG 4 0 1 2 5 2 5 3 MMA IG Tig 5 2 A31 5 3 RU...

Страница 18: ...cmha2p11 cmha2p10 bh31d1r 18 5 4 5 5 MA Arc 152i Arc 152i 1 6 3 25 MMA 2 60 5 6 TIG TIG TIG Arc 152i TIG RU...

Страница 19: ...bh31d1r 19 TIG Arc 152i TIG TIG scrape start TIG scrape start 6 6 1 RU...

Страница 20: ...bh31d1r 20 7 8 ESAB ESAB ESAB 9 RU...

Страница 21: ...notes 21 NOTES...

Страница 22: ...ESAB AB 2008 Diagram bh31e 22...

Страница 23: ...ESAB AB 2008 bh31e 23...

Страница 24: ...152i ESAB AB 2008 Order number bh31o 24 Ordering no Denomination Type 0460 445 880 Welding Power source Caddy Arc 152i A31 for 230 V mains voltage 0459 893 027 Spare parts list Caddy Arc 151i Arc 152i...

Страница 25: ...2008 Accessories bh31a11a2 25 Welding cable kit Return cable kit 0700 006 898 0700 006 899 Strap 0460 265 001 Cable holder 2 pcs 0460 265 002 Shoulder strap 0460 265 003 Trolley for 5 10 litre gasbot...

Страница 26: ...notes 26 NOTES...

Страница 27: ...notes 27 NOTES...

Страница 28: ...34 91 878 3600 Fax 34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel 46 31 50 95 00 Fax 46 31 50 92 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Di...

Отзывы: