−
13
−
dpb1d1ea
6.6.2
Schematic pulsed welding sequence:
6
1. The gas preflow time is preset at 10 ms.
2. Hot start:
S
The start current is preset at 100 A.
S
The time is adjusted on the front panel: 20
−
500 ms.
(For MMA welding: 200
−
2000 ms.)
3. The start current is 15 A.
4. The slope
−
up time is adjusted on the front panel: 0
−
10 s.
5. The pulse current is adjusted on the front panel: 5
−
250 A.
6. The background current is adjusted on the front panel: 10
−
90% of the pulse
current.
7. The slope
−
down time is adjusted on the front panel: 0
−
10 s.
8. At termination, the current is pre
−
set to 5 A.
9. The gas postflow time is adjusted on the front panel: 3
−
30 s.
GB
Содержание Aristotig255 AC/DC DTE 255
Страница 16: ...Edition 031110 Diagram 16 dpb1e11a ...