12
−
dpb1d1ea
6.6
TIG welding
In TIG welding the torch trigger has three different functions:
S
Two
−
stroke
S
Four
−
stroke
S
Four
−
stroke with the possibility to shift between two currents (shift function).
6.6.1
Adjusting the control panel for TIG welding
S
Connect the TIG burner and the earth lead into the OKC outputs E and F, (for
central connection: terminals P and F).
S
Set switch (1) to the desired position.
If a foot
−
operated remote control unit is to be used, set switch (1) to position
two
−
stroke.
NB.
For direct current control over the
foot
−
operated remote control unit, the
potentiometer (7) and (10)
must
be set to position 0.
A hand
−
operated remote control unit can be used for both two
−
stroke and
four
−
stroke to set the welding current.
S
Select the desired striking method using switch (2).
S
Adjust the welding current using potentiometer (8).
S
Select the desired type of pulsing using switch (3).
S
For the shift function/pulsing, adjust the lower current value using potentiometer
(9).