7.

 

Clean the outside of the Heat Exchanger Core. You can use compressed air or water. 
You can do this cleaning inside the building or outside. You can also decide to insert 
a spare Heat Exchanger Core if you have one. 

 

8.

 

Clean the inside of the SS Housing if you notice a lot of dirt. This step does not 
influence the efficiency of the heat exchanger. 

 

9.

 

If necessary, clean the Dispenser with a damp cloth and wipe with a dry cloth. 

 

 

 

 

Содержание ESA-1000

Страница 1: ...USER MANUAL ESA 1000 January 2019 Version 1 0 ...

Страница 2: ...teel Kit 9 3 2 5 Mounting the Stainless Steel Housing 11 3 2 6 Mounting the ESA Controller 13 3 2 7 Wiring the Fan Module 14 3 2 8 Connecting and positioning the Temperature Sensors 17 3 2 9 Connecting the Actuator 18 3 2 10 Interlocking your ESA Controller with your Ventilation Controller 18 3 2 11 Connecting the power to the ESA Controller 18 4 HEAT EXCHANGER SPECIFICATIONS 19 5 USE AND SETTINGS...

Страница 3: ...Operating Modes Sub menu of control 0 10V 28 5 13 Operating Modes Sub menu of control Slave 28 5 14 System settings Sub menu of configuration 28 5 15 Software update 35 6 Maintenance 36 6 1 Regular maintenance 36 6 2 Annual maintenance 40 6 3 Parts 40 7 TROUBLESHOOTING 41 8 LIMITED WARRANTY 42 ...

Страница 4: ... s Installation and use that does not comply with the instructions in this manual are hazardous may cause damage to your building and will void your product warranty Installations may vary depending on the position in which the unit s are installed The illustrations in this document may differ slightly from your installation Use the illustrations as guides to help you understand the installation p...

Страница 5: ...premature blockage of the unit clean the Heat Exchanger Core once a flock herd or as required You can also purchase spare ones ATTENTION To reduce the risk of fire electric shock injury or death you must abide by these safety precautions and guidelines and failure to do so may result in injury or death to user product and property 1 The ESA 1000 heat exchanger is intended for agricultural installa...

Страница 6: ...ny mechanical electrical control device combustion equipment and other air inlets or outlets without consulting with ESA 10 Do not use to vent dangerous explosives or flammable substances 11 When installing servicing or cleaning the unit s wear safety goggles gloves and helmet 12 If the regulations in force in a region are more stringent than those found in this document they must be respected The...

Страница 7: ...ontroller o 4 Temperature Sensors Stainless Steel SS Kit o 2 SS L Bars o 4 SS Chains o 18 SS Screws o 4 Turnbuckles o 10 Quick Links o 2 Snap Hooks Basic Carpentry Tools o Safety Gloves Glasses o Drill o Circular Saw o Silicone o Philips Screwdriver o Allen Key o Ladder o Bolt Cutters o Level FIGURE 1 COMPLETE HEAT EXCHANGER Fan Module Plenum Sainless Steel Housing Heat Exchanger Core inside SS Ho...

Страница 8: ...or your type and size of building Gather and transmit the following details when speaking with your ESA certified representative Your minimum and stage one ventilation requirements Know the position of your fresh air inlets and exhaust fans Have a look at the available wall space on the inlet and exhaust sides of your barn Width length of the barn and the ceiling height at the side walls Know the ...

Страница 9: ... the Fan Module into see IMAGE 1 IMAGE 1 3 2 Installation of the ESA 1000 3 2 1 Installation of the Fan Module WARNING Always lift the SS Housing with two people This Dual Flow Fanä module provides 100 fresh air and exhausts stale air outside 1 Slip the Fan Module through the hole in the wall see IMAGE 2 IMAGE 2 ...

Страница 10: ...by keeping the drainage channel on the bottom see IMAGE 3 IMAGE 3 3 Screw the Fan Module to the wall using six SS screws as provided by ESA three on the left and three on the right side You can screw through the plastic on each side of the Fan Module as shown below and for maximum strength be sure to screw into the studs that were used for framing the hole ...

Страница 11: ...ule 2 Lift the Plenum up into position by positionning the bottom edge into the socket under the SS face plate see IMAGE 4 IMAGE 4 3 Push back on the top of the Plenum until the top edge slips into the socket below the handle 4 Reinstall the SS plate as it was prior to loosening it Make sure all screws are tightened securely 3 2 3 Installation of the Stainless Steel L Bars WARNING Failure to screw...

Страница 12: ...vided or longer screws as required in order to secure the SS L Bars to the ceiling joists The center of the SS L Bars should be aligned with the center of the hole made previously The first SS L Bar must be installed on the ceiling 21 inches in from the wall and the second SS L Bar must be installed on the ceiling 61 inches in from the wall see IMAGE 5 IMAGE 5 3 2 4 Assembly and Installation of th...

Страница 13: ...r rail each 20 inches from the center of the rail and aligned with the outside edges of the Plenum Install the two chains with the clips on the left side and install the two chains with the hooks on the right side Adjust the height by turning the turnbuckles see IMAGE 7 IMAGE 7 ...

Страница 14: ...s right side up NOTE The heat exchanger s must be installed with a slight inclination to the outside wall for proper drainage of the humidity accumulated from condensation build up in and around the Heat Exchanger Core Approximately to inch higher in the back versus the front 1 Hang the SS Housing on the left side using the two chains that have clips Make sure the SS Housing is right side up and p...

Страница 15: ...ld be a slight inclination towards the wall to evacuate condensation see IMAGE 9 IMAGE 9 3 Tighten the Plenum to the SS housing by adjusting the 6 fasteners Make sure they are tight enough to provide a good seal see IMAGE 10 4 Use Silicone if required to seal around the Fan Module see IMAGE 10 IMAGE 10 Fasteners Silicone ...

Страница 16: ...ge wires equipment Make sure the wires are connected securely Before fixing the ESA Controller to the wall 1 Unscrew the 4 screws from then ESA Controller interface panel 2 Unplug the interface panel and place it in a safe place 3 Drill three holes under the ESA Controller housing Be careful not to drill directly under the electrical terminals of the ESA Controller to avoid damaging them 4 Install...

Страница 17: ...changer to connect the temperature sensors the Actuator and the fan motor see IMAGE 12 IMAGE 12 3 2 7 Wiring the Fan Module Motor connection 1 Pass the motor wire through the right cable gland 2 Plug the black wire into the motor terminal 3 Connect the red wire to the COM L2 terminal 4 Plug the green wire into the ground terminal ...

Страница 18: ...ESA 1000 USER MANUAL 15 FIGURE 2 WIRING DIAGRAM ...

Страница 19: ...ESA 1000 USER MANUAL 16 ...

Страница 20: ...he left cable gland 2 Connect the white wire of the T1 sensor to the T1 terminal and the black wire to the GND terminal immediately to the right 3 Connect the white wire of the T2 sensor to the T2 terminal and the black wire to the GND terminal same terminal as the T1 sensor black wire 4 Connect the white wire of the T3 sensor to the T3 terminal and the black wire to the GND terminal immediately t...

Страница 21: ...ith the temperature sensors and the Actuator b Plug the red wire into the 0 10 V terminal c Plug the black wire into the GND terminal immediately to the right d If you have multiple heat exchangers you can run the 0 10vdc wire in parallel e Do not forget to install a jumper between GND and DIN terminals 3 2 11 Connecting the power to the ESA Controller NOTE The motor requires a 240V power source f...

Страница 22: ... 230lbs 105kg DIMENSIONS See FIGURE 4 below FAN MODULE MOTOR FAN ASSEMBLY HP 1 2 PHASE PH1 HZ 50 60 Hz PROTECTION Automatic reset overload RPM 1625 REPLACEMENT Compatible with EC smart motors WEIGHT 77lbs 35kg Fan assembly ESA CONTROLLER MATERIAL ABS Plastic WEIGHT 2lbs 1kg DISPLAY 1 5 x 3 Liquid Crystal Display DIMENSIONS Width 8 Height 6 Depth 3 CERTIFICATIONS CSA and ETL approved POWER REQUIRED...

Страница 23: ...y Modbus protocol PLENUM MATERIAL Polystyrene WEIGHT 20lbs 9kg DIMENSIONS see reverse SS HOUSING MATERIAL SS double layer DIMENSIONS see reverse INSULATED Yes with foam Expanded Polystyrene WEIGHT 98lbs 45kg HEAT EXCHANGER CORE MATERIAL Polystyrene WEIGHT 29lbs 13kg Note Weights and dimensions are rounded off to the nearest whole number ...

Страница 24: ...ESA 1000 USER MANUAL 21 FIGURE 4 ...

Страница 25: ...ESA 1000 USER MANUAL 22 5 USE AND SETTINGS ESA CONTROLLER 5 1 User Interface User Keys and LED Indicators 5 2 User Interface Temperature Sensors ...

Страница 26: ...ESA 1000 USER MANUAL 23 5 3 Home Screen 5 4 Main Menu Home Button ...

Страница 27: ...ESA 1000 USER MANUAL 24 5 5 Main Menu History Button 5 6 Settings of History ...

Страница 28: ...ESA 1000 USER MANUAL 25 5 7 Settings of History 5 8 Settings of History ...

Страница 29: ...ESA 1000 USER MANUAL 26 5 6 Main Menu Control Button 5 8 Operating Modes Manual ...

Страница 30: ...ESA 1000 USER MANUAL 27 5 9 Operating Modes Stand alone 5 10 How to program the Stand alone Mode ...

Страница 31: ...ESA 1000 USER MANUAL 28 5 11 Operating Modes 0 10 5 12 Operating Modes Slave ...

Страница 32: ...ESA 1000 USER MANUAL 29 5 13 Main menu Production 5 14 Setting of Production ...

Страница 33: ...ESA 1000 USER MANUAL 30 5 15 Main menu Defrost 5 16 Defrost modes ...

Страница 34: ...ESA 1000 USER MANUAL 31 5 17 Main menu Configuration 5 18 Local settings ...

Страница 35: ...ESA 1000 USER MANUAL 32 5 19 Advanced parameters 5 20 Backlight ...

Страница 36: ...ESA 1000 USER MANUAL 33 5 21 Start 100 5 22 Drying ...

Страница 37: ...ESA 1000 USER MANUAL 34 5 23 Traps 5 24 USB ...

Страница 38: ...nstalled Follow the steps below Delete all files on the USB Copy and paste the new software file to the USB DO NOT change the name of the file and make sure the USB only contains the new software file Make sure the heat exchanger ESA controller is powered on Remove the front cover of the ESA controller by removing the four screws Observe the speed of the green blinking LED on the top left corner p...

Страница 39: ... breaker is shut off and disconnect any power NOTE For optimum efficiency it is advisable to service the unit periodically 6 1 Regular maintenance To do between each flock herd 38 40 days 1 Turn off the power 2 Detach the fasteners between the Plenum and the exchange module 3 Separate the Plenum from the SS Housing ...

Страница 40: ...rtical position by removing the hooks from the right side 5 Remove the Dispenser at the end of the unit by removing the two clips and pulling out on the Dispenser Place it in a safe place with its 2 screws 6 Remove the Heat Exchanger Core from the SS Housing ...

Страница 41: ... cleaning inside the building or outside You can also decide to insert a spare Heat Exchanger Core if you have one 8 Clean the inside of the SS Housing if you notice a lot of dirt This step does not influence the efficiency of the heat exchanger 9 If necessary clean the Dispenser with a damp cloth and wipe with a dry cloth ...

Страница 42: ...clean the drain to make sure there is no dust accumulated 12 Insert the Heat Exchanger Core back into the SS Housing and put back the Dispenser 13 Return the SS housing back to its original horizontal position 14 Tighten the Fasteners between the Plenum and the SS Housing ...

Страница 43: ...Parts Many producers prefer to purchase several Heat Exchanger Cores in order to speed up regular maintenance during the winter season In order for your ventilation unit to remain in good operating condition only the manufacturer s replacement parts must be used The manufacturer s original replacement parts are designed specifically for each unit and are developed to meet the highest standards of ...

Страница 44: ...the main electrical panel Check the circuit breaker of the unit Check that you have 240V at the electrical outlet Check that the main switch is firmly on Report the problem to ESA Unit does not work or airflow is very low under 25 C 13 F Check the 4 temperatures on the control panel and determine whether there is heat exchange or not Report the problem to ESA ...

Страница 45: ...ve no further obligation under this limited warranty All warranty obligations of Energy Solutions Air are extinguishable if the Product has been subject to abuse misuse negligence or accident or if the Purchaser fails to perform any of the duties set forth in this limited warranty or if the Product has not been operated or installed in accordance with instructions or if the Product serial number h...

Отзывы: