ROUTINE MAINTENANCE
C
Grease the center oscillation pivot
[C]
every
40 hours
of operation.
NOTE:
The attachment must be disconnected from
the loader in order to access this grease zerk.
Visually inspect the eight isolation mounts (four on
each end) for cuts or tears
weekly
.
IMPORTANT:
If a rubber isolation mount has a cut or
tear, it must be replaced. If it is not replaced, the
remaining good isolation mounts will be put under
more load, which will result in premature isolation
mount failure.
IMPORTANT:
Rubber isolation mounts that have a
permanent deformation should be replaced.
40