DESCRIPTION OF THE PRODUCT
Descripcion_144.fm -
20/1/12
VIVO-D201 Control board
49
24Vdc battery (
bA
)
It is possible to connect a battery in order for the
operator to continue working in the event of a drop in
power. The battery will be recharged when the
electricity supply is restored.
The battery must be connected to the control board
t h r o u g h a c h a r g e r , a s e x p l a i n e d i n “ B a t t e r y
connection” on page 58.
3
FUNCTIONING MODES
Automatic mode (
F101
)
Opening:
this begins by activating the key device
(magnetic key, key switch, transmitter, etc).
•
Collective opening (
A901
):
during opening, the
control board does not obey key commands (the
gate cannot be halted using key devices).
•
Step-by-step opening (
A902
):
if a key command is
sent during opening, the gate comes to a halt. A key
command must be sent to close it. A new key
command after closing produces a reset (
rS
).
•
Opening with alternative shutdown (
A903
):
if a
key command is sent during opening, the gate halts
and remains open for the programmed time. If a key
command is sent during standby, standby time
starts again. A new key command after closing
produces a reset (
rS
).
Standby:
t h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time (except with the option
A902
, which
remains open until a key command is received). The
effect of activating the photocells or key device during
standby depends on the parameters
A8
and
A7
respectively.
Closing:
the closing operation starts once stand-by
time is finished.
If the key device is operated during closing, the gate
halts, reverses operation direction and then opens
completely.
Step-by-step mode (
F102
)
Opening (with alternative shutdown):
this begins
by activating the key device (magnetic key, key switch,
transmitter, etc).
•
Step-by-step opening (
A901
,
A903
):
if a key
command is sent during opening, the gate comes to
a halt. A key command must be sent to close it. A
new key command after closing produces a reset
(
rS
).
•
Collective opening (
A902
):
during opening, the
control board does not obey key commands (the
gate cannot be halted using key devices).
Standby:
the gate remains open indefinitely until the
key device is operated.
Closing:
the closing operation starts when the key
device is operated.
If the key device is operated during closing, the gate
halts, reverses operation direction and then opens
completely.
Dead man mode (
F103
)
Opening:
this is done by continuously operating the
ST1 key device (magnetic key, key switch, pushbutton,
etc). The radio transmitter cannot be used in this case.
Standby:
the gate remains open indefinitely until the
key device is operated.
Closing:
this is done by continuously operating the ST2
key device (magnetic key, key switch, pushbutton, etc).
The radio transmitter cannot be used in this case.