¡ ATTENTION ! The 24Vdc flash light output is not fixed output but flashing. To connect a fixed or a fixed mode flash 
light for the proper Function.
NOTE (Parameter F9)

Exterior Photocell: Only be activated in case of door closing.

Interior Photocell: Can be activated in door opening and door closing..

Complete programming chart (1)

Encoder/ Limit switch

Number of operators

Maximum trapping force

Gate speed

Slowdown

Soft stop speed

Lapse between leaves in

opening and closing

Semi-automatic or 

automatic

operation mode and 

stand-by

time (in seconds) in 

automatic

mode

Photocell Function mode 

(Open-close,

interior-exterior)

Pedestrian opening

Flashing light pre-warning

F1

F2

F3

F4

F5

F6

F7

F8

F9

FA

FB

F1-1

F1-2

F1-3

F2-1

F2-2

F3-1

F3-2

F3-3

F3-4

F4-1

F4-2

F5-1

F5-2

F6-1
F6-2

F7-1

F7-2

F7-3

F7-4

F7-5

F7-6

F7-7

F7-8

F7-9

F8-0

F8-1

F8-2

F8-3

F8-4

F8-5

F8-6

F8-7

F8-8

F9-1

F9-2

F9-3

F9-4

FA-0

FA-1

FB-0

FB-1

Motor only 

Motor with limit switch

Motor with encoder

Two Operators

One Operator

2A

3A

4A

5A

100% Full Speed

80% Full Speed

Function ON

Function OFF

70% Full Speed
50% Full Speed

F6-3

35% Full Speed

F6-4

25% Full Speed

2 sec.

3 sec.

4 sec.

5 sec.

6 sec.

7 sec.

8 sec.

9 sec.

10 sec.

OFF

3 sec.

10 sec.

20 sec.

40 sec.

60 sec.

120 sec.

180 sec.

300 sec.

Mode 1

Mode 2

Mode 3

Mode 4

OFF

ON

OFF

On

1. The factory setting is  "F1-1".

1. The factory setting is "F2-1".

1. The factory setting is  "F3-1".

2. Please make sure that the parameter F3 is always in F3-1

    in case of system learning process. 

1. The factory setting is "F4-1".

1. The factory setting is "F5-1".

1. The factory setting is  "F6-2".

1. The factory setting is "F7-1".

1. The factory setting is "F8-0".

1. The factory setting is "F9-1".
Mode 1: Photocell Exterior FT1- Photocell Interior FT2
Mode 2: Photocell Exterior FT1- Safety Belt FT2
Mode3: Photocell Exterior FT1- Open Device FT2
Mode 4: Photocell Interlock FT1- Fotocélula Interior FT2
1. When Function on and push B key in the transmitter, one 
    gate will open partically.
2. The factory setting is "FA-0".

1. When Function ON, the light will flash before the gate 
    operate 3 seconds. If set OFF, the flash light will operate 
    with motor in the same time.
2. The factory setting is  "FB-0".

LED Display               Definition             Parameter 

        Mode 

                                     Description

Содержание TEMIS

Страница 1: ...ening TEMIS It is not applicable to an insecure or lacking rigidity door nor solves the defects due to incorrect installation or mainte Check the following points before starting the installation 1 Hi...

Страница 2: ...completely horizontally Place the motor on rear bracket with screw A and nut B 1 1 1 Insert the key to the release slot 2 Turn counterclockwise to release the motor 1 Insert the key and turn clockwise...

Страница 3: ...on extention Opening Time Duty Cycle Protection Grade IP Operation temperature Absorbed current A Absorbed Power W Manual Release Enclosure Dimensions 2 2M 200kg 110V 230VAC 50 60Hz SMART D201M SMART...

Страница 4: ...3 K2 K1 J4 J3 J7 F1 DB1 J8 NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED3 LED4 LED2 LED Display LED1 System Learning LED2 RF Lea...

Страница 5: ...setting You would continue setting F2 2 please press SET to return the formal option The LED display shows the first two numbers as the first option F1 And then follow the operation and 2 3 until comp...

Страница 6: ...6 0 ORVH 0 2SHQ 0 ORVH Advise If change the configuration of F2 you should program the system learning again The completion of system learning A For Double leaf gate D G installation Show RUN on LED...

Страница 7: ...100 Full Speed 80 Full Speed Function ON Function OFF 70 Full Speed 50 Full Speed F6 3 35 Full Speed F6 4 25 Full Speed 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec 9 sec 10 sec OFF 3 sec 10 sec 20 sec...

Страница 8: ...on key Pedestrian Mode Function key Auto Close Function key FC FD FE FF FG FH FI FC 0 FC 1 FD 0 FD 1 FE 0 FE 1 FF 0 FF 1 FG 1 FG 2 FG 3 FG 4 FH 0 FH 1 FH 2 FH 3 FH 4 FI 0 FI 1 FI 2 FI 3 FI 4 OFF ON OF...

Отзывы: