Complete programming chart (2)

Note (Parameter F3)

Please set F3 Function after system learning. The LED display 10 to indicate all of the recorded values will increase 1 ampere as
the over current value. In other words, the LED shows 20 to indicate all the recorded values will increase 2 ampere as the over
current value. The value can be adjusted by pressing button UP and DOWN. The maximum value is 40(4.0A) and the minimum 
value is 05 (0.5A) 

LED Display               Definition             Parameter 

        Mode 

                                     Description

Photocell1

Photocell2

Buzzer Function

Reverse Impulse for 
Electric Lock

Open/Stop/Close/Stop
Function key

Pedestrian Mode Function 

key

Auto-Close Function key

FC

FD

FE

FF

FG

FH

FI

FC-0
FC-1
FD-0
FD-1
FE-0
FE-1
FF-0
FF-1

FG-1
FG-2
FG-3
FG-4
FH-0
FH-1
FH-2
FH-3
FH-4
FI-0
FI-1
FI-2
FI-3
FI-4

OFF

ON

OFF

ON

OFF

ON

OFF

ON

A key
B key

C key
D key

OFF

A key
B key

C key
D key

OFF

A key
B key

C key
D key

1. The factory setting is "FC-0".

1. The factory setting is "FD-0".

1. The factory setting is "FE-0".

1. if the Function is on, the gate will move forward a 
little  before the gate operate for releasing  the Latch 
2. The factory setting is "FF-1".

1. The factory setting is "FG-1".

1. The factory setting is "FH-2".

1. The key is to turn on or off the Auto-Close Function.
2. The factory setting is "FI-0".

3. When the  flasher and buzzer is running, the auto 
    closed button has no Function till flasher and buzzer 
    finish running.

Содержание TEMIS

Страница 1: ...ening TEMIS It is not applicable to an insecure or lacking rigidity door nor solves the defects due to incorrect installation or mainte Check the following points before starting the installation 1 Hi...

Страница 2: ...completely horizontally Place the motor on rear bracket with screw A and nut B 1 1 1 Insert the key to the release slot 2 Turn counterclockwise to release the motor 1 Insert the key and turn clockwise...

Страница 3: ...on extention Opening Time Duty Cycle Protection Grade IP Operation temperature Absorbed current A Absorbed Power W Manual Release Enclosure Dimensions 2 2M 200kg 110V 230VAC 50 60Hz SMART D201M SMART...

Страница 4: ...3 K2 K1 J4 J3 J7 F1 DB1 J8 NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED3 LED4 LED2 LED Display LED1 System Learning LED2 RF Lea...

Страница 5: ...setting You would continue setting F2 2 please press SET to return the formal option The LED display shows the first two numbers as the first option F1 And then follow the operation and 2 3 until comp...

Страница 6: ...6 0 ORVH 0 2SHQ 0 ORVH Advise If change the configuration of F2 you should program the system learning again The completion of system learning A For Double leaf gate D G installation Show RUN on LED...

Страница 7: ...100 Full Speed 80 Full Speed Function ON Function OFF 70 Full Speed 50 Full Speed F6 3 35 Full Speed F6 4 25 Full Speed 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec 9 sec 10 sec OFF 3 sec 10 sec 20 sec...

Страница 8: ...on key Pedestrian Mode Function key Auto Close Function key FC FD FE FF FG FH FI FC 0 FC 1 FD 0 FD 1 FE 0 FE 1 FF 0 FF 1 FG 1 FG 2 FG 3 FG 4 FH 0 FH 1 FH 2 FH 3 FH 4 FI 0 FI 1 FI 2 FI 3 FI 4 OFF ON OF...

Отзывы: