SKY electromechanical operator
21
INSTALLATION
6
ELECTRICAL CONNECTIONS
STOP
P93X
6
7
1
6
7
P93V
Operator parts SK110:
C:
Capacitor
D:
Unlock switch
K:
Thermal protector
FCA:
Opening limit switch
FCC:
Closing limit switch
FCS:
Additional limit switch (to be used
in accordance with the
requirements of the customer or
installation)
Control board parts (AM606S):
DL4:
Open LED
DL5:
Close LED
PUL1:
Close mini-pushbutton
PUL2:
Open mini-pushbutton
SW1
:
Main switch
Operator connections SK110:
1
Opening limit switch (FCA)
2
FCA and FCC limit switches common
3
Closing limit switch (FCC)
4-5
Additional limit switch (FCS)
6-7
Thermal protector / unlock switch
UP
Open (RL1)
DOWN
Close (RL2)
N
Common
PE
Earth connection
When pressing PUL1 (close), DL5 lights
up and the COM and RL2 cable
connectors are activated.
When pressing PUL2 (open), DL4 lights
up and the COM and RL1 cable
connectors are activated.
If the operator turns in the opposite
direction to that required, interchange
connections RL1 and RL2.
AM606S
SK110
SINGLE PHASE OPERATORS (SK110E and SK110C)
We recommend control board AM606S
Connection to switchboard without STOP cable connectors
Although not recommended, it is possible to use a
switchboard which does not have STOP cable
connectors. In this case, make the connections as
shown in the diagram (D and K connect in series to
the COM cable connector of the limit switches).
O
If K or D is activated (operator overheated
or unlocked), do not run PUL1 or PUL2
(open and close mini-pushbuttons) as this
may cause damage to the operator.