Mantenimiento_93 v04.fm -
13
/6/1
8
24
Installation Guide
MAINTENANCE AND DIAGNOSIS OF FAILURES
1
MAINTENANCE
Before carrying out any maintenance
operation, disconnect the device from the
power supply.
1
Frequently check the installation in order to discover
any imbalance or sign of deterioration or wear. Do
not use the device if any repair or adjustment is
necessary.
2
Clean and lubricate the joints of the door and the
operator supports, so as not to increase the effort of
the operator.
3
Check that the operation and safety devices, as well
as their installation, have not suffered any damage
from the weather or external agents.
4 OIL LEVEL
: during maintenance operations, check
that no leakage of oil can be observed in the gear
box. If leakages are observed, contact Erreka
technical service. It is not necessary to replace the oil
during the useful life of the device.
To know the type of oil to use, see “Gear box oil”
on page 16.
2
FAILURE DIAGNOSIS
3
SPARE PARTS
If the operator needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
Use only original spare parts.
4
SCRAP
The operator, up until the end of its useful life,
must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner we will avoid possible accidents and
damage to adjacent facilities.
}
The operator must be deposited in the appropriate
containers for subsequent recycling, separating and
classifying of the different materials in line with their
nature. NEVER deposit it in domestic rubbish or in
landfills which are not controlled, as this will cause
environmental damage.
Problem
Cause
Solution
The operator does not make
any movement when the
opening or closing controls
are activated
Absence of system power supply
voltage
Re-establish the power supply
Electrical installation defective
Check that the installation does not
present any short-circuits or cut-off
points
The thermal protector has been
activated
Wait for the operator to cool down
Control board or key commands
defective
Check these elements, seeing their
respective manuals
When activating the opening
or closing devices, the
operator is activated but the
door does not move
Door obstructed or blocked
Unlock, adjust and lubricate the door
joints
U n l o c k o p e r a t o r f o r m a n u a l
operation
L o c k t h e o p e r a t o r ( s e e “ M a n u a l
operation” on page 18).
The door moves in an
irregular manner
D o o r p a r t i a l l y o b s t r u c t e d o r
blocked
Unlock, adjust and lubricate the door
joints
The door cannot completely
close (or open)
Th e saf e ty de vic e d e te ct s a n
obstacle
Remove the obstacle and try again
The resistance of the door has
increased when closing (or when
opening)
Check the moving parts of the door and
remove the resistance
The thrust of the operator during
closing (or opening) is too low
Increase the closing or opening thrust
using the control board programming.