English
Descripcion_93 v0
4.fm - 13/6/18
SKY electromechanical operator
15
DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
For greater safety, Erreka recommends installing the
photocells (4).
INSTALLATION COMPONENTS:
1
Operator
2
Wall pushbutton
3
Control board
4
Photocells
5
Antenna
ELECTRICAL CABLING:
Element
Nº threads x section
Maximum length
A: Main power supply
SK110: 3x1.5 mm
2
SK130, SK135: 5x1.5 mm
2
30m
B: plug-in receiver
3x0.5 mm
2
20m
C: Photocells (Tx / Rx)
2x0.5 mm
2
/ 4x0.5mm
2
30m
D: Pushbutton
2x0.5 mm
2
25m
E: Operator / Limit switches
4x1 mm
2
/ 4x0.5mm
2
20m
F: Antenna
Screened cable