E
N
G
L
IS
H
35
Press the
-
key,
the display shows
8
Press the
key:
0
flashes
to indicate that the function
is deactivated
Press the
+
key to activate
the function: the display
shows
I
Press the
key to save
the settings: the display
shows
8
8. Maintenance alarm (default: 0 – function deactivated)
If this function is activated, the device emits BEEPs when the motor reaches 2000 operational cycles.
This alarm may be useful for scheduling maintenance operations.
To interrupt the alarm , simply press and hold the START button for 5 seconds, or power off the device for several seconds.
10. End of programming
Follow the procedure set out below to leave the programming stage and store the programming of the different parameters
Press the button
for five seconds the menu
(e.g.
9
) flashes
Release the button:
the screen segments come
on one at a time until
0
is
displayed
Press the
-
button and the
screen will display
9
Press the
button:
0
flashes to indicate
Alternative Stop Operation
Press the
+
button to change
to Collective Opening
Operation: the screen
displays
1
9. Operation with Alternative Stop/Collective opening (By defect: 0 – Alternative Stop Operation)
This menu can be used to select the automation mode during opening and closing.
Operation with Alternative Stop: Pressing the button and/or remote-control interrupts the operation during the Opening stage (and the
automatic cycle is not respected if enabled), and the gate completely reopens during the Closing stage. In gate open, pressing the button or
remote control closes the gate.
Collective Opening Operation: During the Opening stage the operation will not be interrupted if the button and/or remote control is
pressed, whilst during the Closing stage the gate opens again completely.
In gate open with automatic cycle enabled it restarts standby time, whilst in step-by-step cycle it closes the gate.