background image

Pag. 10

Menu : Modify User

This procedure is at the item 3 of the main menu.
Through this procedure it is possible to carry out the 
following actions on a USER transmitter, only if it is present 
in the memory:

!

Modify the activated relay and the corresponding 

transmitter key;

!

Enable or disable the single USER

M  O  D  I  F  Y 

 

U  S  E  R 

   

   

   

       

U  S  E  R 

    S  N 

 

2  0  6  0  9 

   

   

   

 

Set the Serial Number of the transmitter to modify by 
using the 3 methods allowed ( TX MASTER, KEYPAD, Key 
B of the USER TX )
Then give the confirmation with the key YES of the TX 
MASTER

User Enable / Disable

The receiver checks the current situation and propose the 
corresponding changement 
- If the USER transmitter id enabled, it asks to disable;
- if the USER transmitter is enabled, it asks to enable

U  S  E  R    

  

 

   S  N     2  0  6  0  9 

D  I  S  A  B  L  E    U  S  E  R     ?    

  

 

U  S  E  R    

  

 

 

S  N   

2  0  6  0  9 

E  N  A  B  L  E    

  U  S  E  R     ?    

  

 

With a final YES appears the message EXECUTED OK, 
the transmitter is disabled, the procedure ends and the 
program returns to the main menu.
If the transmitter is currently disabled, you are asked to 
enable.

With an answer YES the following message appears:

D  I  S  A  B  L  E    U  S  E  R   

 

 

 

A  R  E     Y  O  U   

S  U  R  E   

  

  

 

With a final YES appears the message EXECUTED OK, 
the transmitter is enabled, the procedure ends and the 
program returns to the main menu.

With an answer YES the following message appears:

E  N  A  B  L  E    

  U  S  E  R   

 

 

 

A  R  E     Y  O  U   

S  U  R  E   

  

  

 

Modify relay or key parameters 

Once selected the Serial Number of the transmitter to 
modify, you are asked to set the relay and the key 
parameters:

U  S  E  R    

  

 

   S  N     2  0  6  0  9 

R  E  L  A  Y     O  R     K  E  Y      ?    

  

 

With a YES,it is displayed the current configuration of the 
transmitter: activated relay and corresponding transmitter 
key.
The following table shows the association between relays 
and keys when the parameter RELAY is set to ½:

2-keys transmitter

  

Key Option

A

B

  Activations

A - Relay 1

B - Relay 1

B - Relay 2

A - Relay 2

4-keys transmitter

  Key Option

A

B

C

D

  Activations

A -Relay 1 B -Relay 1 C -Relay 1 D -Relay 1
B -Relay 2 C -Relay 2 D -Relay 2 A -Relay 2

If the parameter RELAY is set to 1 or 2, only the key 
indicated causes the activation of the relay.

U  S  E  R    

  

 

   S  N     2  0  6  0  9 

R  E  L  A  Y  :  ½    

  

 

  K  E  Y  :   A  

 

Once inside the options for the parameters RELAY and 
KEY, scoll the options available with the LEFT key of the 
TX MASTER and confirm with the RIGHT key. 

OPTIONS RELAY : 1 - 2- ½ - 1- 2 - etc.
OPTIONI KEY :  A - B - C - D - A - B - etc

.

At the end the message EXECUTED OK appears and the 
program returns to the main menu.

NOTE

 : If you entry the S/N of a transmitter not in 

memory, the following message appears :

S  N     N  O  T     I  N    M  E  M  O  R  Y 

U  S  E  R    

  

  

   S  N     2  0  6  0  9 

 

Содержание SEL2641R433-16P

Страница 1: ...ct This product is addressed to manage the access in automatic door control systems This appliance has been carefully manufactured and checked The manufacturer has designed this system to assure the b...

Страница 2: ...CD trimmer adijust 3 Terminal boards 4 Relay1 5 Relay 2 6 4 pin strip connector 7 RJ11 phone connector 8 Buzzer 9 D type 9 pin male connector 10 Plugs 11 Screws 12 Aerial net 13 Receiver box 1 2 4 3 5...

Страница 3: ...memorization Main menu structure Menu Delete Pag 9 Single user cancellation All users cancellation Complete initialization of the receiver Menu Modify user Pag 10 Enable Disable Modify relay or key p...

Страница 4: ...gs 4 Technical specifications Receiver Carrier frequency 433 92 MHz Local oscillator freq 6 6128 MHz Power supply 12 24 Vac dc Modulation AM ASK Number of memorizable users 812 1631 Number of relays 2...

Страница 5: ...vious menu Activation of the LEFT key Cyclical scroll upwards a digit Activation of the RIGHT key Gives confirmation to the present digit and shifts the cursor to the next digit of the number Number s...

Страница 6: ...ons ERONE advice 2 A telephone wire 0 6 mm is sufficient for the input of the receiver and the relay cabling Receiver power supply connecting clip 3 0V connecting clip 4 12 24 Vac dc Connect the outpu...

Страница 7: ...A S T O R E M A S T E R Where 00000 is the Serial Number of the Master transmitter used With an answer YES the display shows EXECUTED OK and the transmitter is memorized On the first line of the disp...

Страница 8: ...6 1 0 R E L A Y K E Y A Modify the parameters RELAY and KEY according to your needs by using the MASTER transmitter The next step allows to choose a single or a block memorization U S E R S N 2 0 6 1...

Страница 9: ...ee memory and stored TX number will be updated MENU DELETE USER MEM DELETE USER MEM USER DELETE USER MEM ALL USER DELETE USER MEM INIZIALIZE RX DELETE USER MEM ALL USER All users cancellation This opt...

Страница 10: ...the transmitter is enabled the procedure ends and the program returns to the main menu With an answer YES the following message appears E N A B L E U S E R A R E Y O U S U R E Modify relay or key para...

Страница 11: ...r a spare receiver Data recovery from a backup memory Memory Visualization on the LCD The first option allows to visualize the data memory on the LCD display The visualization is carried out line for...

Страница 12: ...to complete the list by hand with more information as the user name and the installation address ERONE 433 800 PASSWORD 11111 FACILITY CODE 000 00_ USER ADDRESS to be filled by hand USER N S N STATUS...

Страница 13: ...of the transmitter card as shown in fig 13 Confirm with the RIGHT key of the MASTER transmitter The software begins the check of the connection P R O G R A M T X U S E R S N 0 0 6 0 9 C O P Y M E M O...

Страница 14: ...the following message appears on the LCD C O P Y M E M O R Y O N N O T C O N N E C T E D Insert the memory or connect the telephone cable and confirm with the RIGHT key of the TX MASTER A warning mes...

Страница 15: ...0 0 0 0 Confirm with the RIGHT key of the MASTER transmitter The password settings can be as follows 1 The current password is Null 00000 password disabled In this case you are asked for the new passw...

Страница 16: ...de FC is a number in the range 000 to 256 sent by the transmitter with its own Serial Number S N The receiver is programmed to accept only transmitters which have 2 types of Facility Codes Any transmi...

Страница 17: ...If the message is persistent check the memory position on the receiver memorize again and then start transfer again Memory full Last memory position use a previous position or replace a position alre...

Страница 18: ...device the connecting cable has to be as follows 1 Connection Receiver RCS 433BMR PC Serial Port D type 9 pin Male connector 2 Connection RCS 433BMR PC Serial Port D type 25 pin Male connector Receiv...

Страница 19: ...ity of the receiver the following accessories are available A TX PROGRAMMING CABLE with PROBE Fig 15 B CONNECTION RECEIVER RECEIVE CABLE fig 16 C SERIAL CABLE to a serial printer Fig 17 D BACKUP MEMOR...

Страница 20: ...9 Fax 39 0438 455 628 E mail info erone com Web www erone com GUARANTEE Warranty period 24 months from the production date placed inside In this period if the appliance has any malfuction due to defec...