Cable connections
It is of utmost importance that all cable connections are carried out exactly as described, in
order to avoid malfunction or damage to the LON
®
Box and/or the connected equipment.
All cables to and from the LON
®
Box are fed through the cable glands. Choose an appropriate
size gland for the actual cable and tighten the glands when all cables are connected.
MAINS IN
N L
SELECT
MAINS
J9
J7
TERM
OFF
S3
B-
B+
RS485 TX
ON
TERM
S2
OFF
ON
S5
115
23
0
RS485 RX/TX
B+
B-
Cable tie
Mains cable
230VAC±10%, 33mA
115VAC±10%, 66mA
45-60Hz
GND
TX RX GND
RS232
LINE LINE
LON
J5
J8
LON
Shield
GND
Rx
Tx
RS
232
+ -
RS485 Rx/Tx
+ -
RS485 Rx/Tx
RS485 termination
J6
In order to fulfil safety standard EN 60950, all cables carrying mains voltage, must be secured
to the PCB by means of e.g. a cable tie, as shown in the above drawing.
LON
®
For details on the LON
®
Network, installation, cabling and termination, please see the
NodeManager S111SX Installation Manual.
To comply with EMC/EMI standard EN 50130-4, shielded LON
®
cable must be used.
Connection is polarity insensitive.
RS232 (I151SX-ALARM)
Connects to a PC COM port, or similar.
v
Data format: 8N1
v
Baud rate: 110 ~ 38400 bps
GND
TX RX GND
RS232
LINE LINE
LON
J5
J8
LON
Shield
GND
Rx
Tx
Pin 5
Pin 3
Pin 2
PC
CO
M
Max. 15 meters
2853-00009
Page 3
S Y S E M