RS232 (I151SX-REMOTE)
Connects to an RS232 port on SYSTEM 500M/1000M.
Serial port (SIO 1 or 2) setup, on SYSTEM 500M/1000M:
v
Type: RS232
v
Device: IEC
v
Baud rate: 19200
For furter details, please see the
Programming Manual
for SYSTEM 500M/1000M.
GND
TX RX GND
RS232
LINE LINE
LON
J5
J8
LON
Shield
GND
Rx
Tx
Pin 5
Pin 3
Pin 2
50
0M
/1
00
0M
S
IO
1 or
2
Max. 15 meters
RS485
The RS485 connections are not used in I151SX-ALARM and I151SX-REMOTE.
Protocols (I151SX-ALARM)
The I151SX-ALARM supports 3 different protocols: SAP, xSAP and IEC.
Serial Alarm Protocol (SAP)
The SAP protocol is a simple alarm protocol, using Xon/Xoff flow control.
Data Format
v
Baud Rate: 1200 ~ 38400
v
Data Bits: 8
v
Parity: None
v
Stop Bits: 1
v
Flow control: Xon/Xoff
Frame format
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
"000" - "512"
41 or 43 Hex
53 Hex
XOR sum
ASCII format
"A" or "C"
"S"
Checksum
Alarm number
Alarm Command
Header
Header
Always ASCII "S" (53 Hex).
S Y S E M
Page 4