background image

Installation

Unpacking the LON

®

 Box

After unpacking the LON

®

 Box, carefully check for any signs of damage. Any such damage

should be reported to your supplier, before installation.

Check that the packing carton contains the following items:

y

1 pcs. SYSTEM X LON

®

 Box.

y

1 pcs. LON

®

 Box X Installation Manual (this manual)

y

1 pcs. screw kit.

Box Installation

Choose a plane surface to prevent the box from being twisted and thereby becoming leaky.
When installed outdoor the box should be oriented with the cable glands pointing
downwards.

Drilling pattern is shown on the back of the box.

Box dimensions (excl. glands) are: 242 x 160 x 90mm (W x H x D).

Mains installation

The LON

®

 Box can be supplied with either 115 VAC or 230 VAC mains voltage. The mains

voltage is selected by the mains voltage selection switch.

T1

MAINS IN

N   L

SELECT

MAINS

J9

Ih

=

63

m

A

F1

S5

115

23

0

Mains selection switch

Mains input
L:
N:
   :

Live
Neutral
Earth

The LON

®

 Box must be used with a 3-wire mains connection (2W+PE @ min. 0,75mm

2

).

Terminals marked with hazardous live symbol requires installation by an instructed person.

If permanently connected to mains, a readily accessible disconnect device shall be
incorporated in the building installation wiring.

If pluggable connection to mains, the socket-outlet shall be installed near the equipment and
shall be easily accessible.

Note: The unit is equipped with two PTC-fuses with automatic reset function. In case of malfunc-
tion always return the unit for repair. The references below are intended for information only.

F1:

 (BC Components, type 2322 660 66393)

I

hold

 = 63mA, I

trip

 = 95mA, Initial resistance = 120R

F2:

 (BOURNS, type MF-R075)

I

hold

 = 750mA, I

trip

 = 1.5A, Initial resistance = 0R18

S Y S E M

Page 2

2853-00009

Содержание LON Box I151SX

Страница 1: ...LON Box X I151SX ALARM I151SX REMOTE Installation Manual 2853 00009 SY S E M...

Страница 2: ...SY S E M...

Страница 3: ...arm protocols IEC Serial Alarm and extended Serial Alarm are supported I151SX REMOTE SYSTEM X to SYSTEM 500M 1000M Interface The I151SX REMOTE interface box is used as an interface between SYSTEM X an...

Страница 4: ...selected by the mains voltage selection switch T1 MAINS IN N L SELECT MAINS J9 Ih 63mA F1 S5 115 2 3 0 Mains selection switch Mains input L N Live Neutral Earth The LON Box must be used with a 3 wire...

Страница 5: ...D TX RX GND RS232 LINE LINE LON J5 J8 LON Shield GND Rx Tx RS232 RS485 Rx Tx RS485 Rx Tx RS485 termination J6 In order to fulfil safety standard EN 60950 all cables carrying mains voltage must be secu...

Страница 6: ...S485 connections are not used in I151SX ALARM and I151SX REMOTE Protocols I151SX ALARM The I151SX ALARM supports 3 different protocols SAP xSAP and IEC Serial Alarm Protocol SAP The SAP protocol is a...

Страница 7: ...tting an extra DC1 character if it wants to transmit DC1 as data Then the receiver knows that two DC1 characters means DC1 data and one DC1 means Xon Example In order to set alarm number 45 ON the fol...

Страница 8: ...smits an Xon to start the transmitter again To be able to send both DC1 and DC3 as data the protocol uses the character stuffing principle Character stuffing means that the transmitter is transmitting...

Страница 9: ...ortly when the service pin is pressed Make sure that the NodeManager software is running and online prior to pressing the service pin It is of out most importance to keep track of the order in which s...

Страница 10: ...East Preston West Sussex BN16 1AW England Phone 01903 77 27 27 Fax 01903 77 27 07 sally ernitec uk co uk www ernitec com Ernitec France French Branch Office No 29 Parc Club du Mill naire 1025 rue Hen...

Отзывы: