background image

 
 
 
 

Page 5 (12) 

 

www.ernitec.com 

4 Field 

of 

View 

The PIR has two curtain-shaped fields of view with independent detection channels for short, medium and long 
range detection. The vertical opening angle is app. 26° resulting in an uninterrupted curtain starting at app. 8 m 
with the detector mounted at 4.0 m (13 ft) height. The nominal ranges and widths at nominal range refer to the table 
below. 

5 Alignment 

The detection range of a PIR detector is not limited but a function of size, speed and temperature contrast of a 
target against its background. The PIR should be aligned so that a natural or artificial background at the end of the 
range terminates the field of view. 
Vertical alignment is optimal when the upper edge of the field of view is at 1.5 to 2.5 m (5 to 8 ft) above ground at 
the end of the required detection range provided that the field of view is properly terminated. 
Coarse alignment can be done visually by looking along the grove on the top of the detector. This line of sight 
corresponds to the upper edge of the detection pattern. Accurate fine alignment is easily achieved with the help of 
the Universal Telescopic Sight ZA P 03, which can be placed on the of the detector for this purpose. 
Where the detection range has to be limited, a terminating screen can be used to avoid detection of targets beyond 
the wanted range. 

Typical vertical alignment for a required detection up to nominal range. 

The PIR should be aligned vertically so that 

at least

 the lower half of a person standing upright at the maximum 

required range will be within the field of view (see Fig. 1 below). 
Side view 

Fig. 1 

Typical horizontal alignment 

Horizontal alignment should be done in a way to avoid unwanted signals being generated by targets (branches, 
bushes, fences) likely to be moved by wind (see Fig. 2 below). Movement within the field of view will reduce the 
sensitivity of the PIR by increasing the alarm threshold level and may lead to unwanted alarms. 
Top view 

Fig. 2 

Definition PIR-100  PIR 

100H 

Nominal Range 

120 m (400 feet) 

150 m (500 feet) 

Width at Nom. Range 

2.7 m (9 feet) 

3.3 m (11 feet) 

Содержание Eagle PIR-100

Страница 1: ...Nominal Range 120 m 400 feet PIR 100H High Performance Nominal Range 150 m 500 feet Highlights Gap Free Coverage with Creep Zones 4 Meter 13 Feet Mounting Height Advanced Tamper Detection Low Power Co...

Страница 2: ...Page 2 12 www ernitec com www ernitec com...

Страница 3: ...Heater H version only 7 14 External Sensitivity Adjustment via RS 485 Data Bus 8 15 Signal Processing 8 16 Accessories 8 16 1 Interface Module PIRIF 485 2 and Installation Software 8 16 2 Pole Mount H...

Страница 4: ...d for wall mounting using screws For pole mounting the original accessory ZA P L1 is available pole mounting bracket with two strap bands for poles of 4 16 cm diameter For further information please r...

Страница 5: ...ve on the top of the detector This line of sight corresponds to the upper edge of the detection pattern Accurate fine alignment is easily achieved with the help of the Universal Telescopic Sight ZA P...

Страница 6: ...eeding a certain minimum value will activate the ATD and increase the threshold levels depending on its strength The time constants for increase and decrease are chosen in a way to adapt to gradual ch...

Страница 7: ...over RS 485 communication All the detectors connected to the same data bus provide all the information relevant to an alarm in a defined protocol frame For further information please contact the manuf...

Страница 8: ...or repeated movements in the field of view the exponential decay of the threshold level to its original value will take app 1 2 minutes from the end of the event Once the threshold level value has be...

Страница 9: ...on is a function of thermal contrast speed and size of a target crossing the field of view Contrast conditions can vary significantly in the course of the day and year Detection depends also on the se...

Страница 10: ...d Output Transistor OC Not used GND Supply voltage 10 5 30 V DC 24 V AC 1 2 3 4 5 6 7 8 50 mA 6 V RS 485 A B 4 7 k 100 mA Sensitivity SW1 SW2 PIR 100 PIR 100H ON ON SW settings ON OFF HW setting maxim...

Страница 11: ...nk it is necessary that the detectors have different addresses IDs For operation with a standard PC a converter to RS 485 is required The interface box is available as accessory 21 1 1 Application of...

Страница 12: ...Weight app 900 g 2 0 lbs incl mounting bracket Cable Feeds 2 x M 16 with cable clamp Outer Cable Diameter 4 5 10 mm 0 18 0 40 inch Electrical Supply Voltage 10 5 30 V DC 24 V AC 15 Current Consumption...

Отзывы: